Bidirectional gated recurrent unit network model can generate future visual field with variable number of input elements
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal Ranking
- JCR Q1Scopus Q1
- Journal
- PLOS ONE19(8) · 2024
- Citation
- Web of Science 3Scopus 4
- FWCI (Scopus)
- 0.26
- JCR IF
- JCR 2023 2.9
- ISSN
- 1932-6203
Authors
- Lee, JoohwangFirst authorCorresponding authorPusan Natl Univ, Coll Med, Dept Ophthalmol, Busan, South Korea
- Park, KeunheungBusan Med Ctr, Busan, South Korea
- Kim, HwayeongPusan Natl Univ, Coll Med, Dept Ophthalmol, Busan, South Korea
- Moon, SangwooPusan Natl Univ, Coll Med, Dept Ophthalmol, Busan, South Korea
- Kim, JunglimInje Univ, Coll Med, Busan Paik Hosp, Dept Ophthalmol, Busan, South Korea
- Jin, SangwookDong A Univ, Coll Med, Dept Ophthalmol, Busan, South Korea
- Lee, SeungukKosin Univ, Coll Med, Dept Ophthalmol, Busan, South Korea
- Lee, Ji WoongCorresponding authorPusan Natl Univ, Coll Med, Dept Ophthalmol, Busan, South Korea
Abstract
Purpose This study aimed to predict future visual field tests using a bidirectional gated recurrent unit (Bi-GRU) and assess its performance based on the number of input visual field tests and the prediction time interval. Materials and methods This study included patients who underwent visual field tests at least four times at five university hospitals between June 2004 and April 2022. All data were accessed in October 2022 for research purposes. In total, 23,517 eyes with 185,858 visual field tests were used as the training dataset, and 1,053 eyes with 9,459 visual field tests were used as the test dataset. The Bi-GRU architecture was designed to take a variable number of visual field tests, ranging from 3 to 80, as input and predict visual field tests at the desired arbitrary time point. It generated the mean deviation (MD), pattern standard deviation (PSD), Visual Field Index (VFI), and total deviation value (TDV) for 54 test points. To analyze the model performance, the mean absolute error between the actual and predicted values was calculated and analyzed for glaucoma severity, number of input visual field tests, and prediction time interval. Results The prediction errors of the Bi-GRU model for MD, PSD, VFI, and TDV ranged from 1.20 to 1.68 dB, 0.95 to 1.16 dB, 3.64 to 4.51%, and 2.13 to 2.60 dB, respectively, depending on the number of input visual field tests. Prediction errors tended to increase as the prediction time interval increased; however, the difference was not statistically significant. As the severity of glaucoma worsened, the prediction errors significantly increased. Conclusion In clinical practice, the Bi-GRU model can predict future visual field tests at the desired time points using three or more previous visual field tests.
Keywords
Identifiers
- Scopus EID
- 2-s2.0-85202506549
- WoS UID
- 001305453900032



Login
Back to Publication list