Development of the Korean Association for Lung Cancer Clinical Practice Guidelines: Recommendations on Radial Probe Endobronchial Ultrasound for Diagnosing Lung Cancer- An Updated Meta-Analysis
- Document Type
- Publications · Journal Article
- Registered DB
- KCISCIEScopus
- Journal Ranking
- JCR Q2Scopus Q1KCI Q1
- Journal
- Cancer Research and Treatment56(2) · pp.464 · 2024
- Citation
- Web of Science 7Scopus 7KCI 0
- FWCI (Scopus)
- 0.79
- JCR IF
- JCR 2023 4.1
- ISSN
- 1598-2998
Authors
- Kim, SooHanFirst authorPusan Natl Univ, Sch Med, Dept Internal Med, Busan, South Korea
- Chung, Hyun SungNatl Canc Ctr, Div Pulmonol, Goyang, South Korea
- Jinmi KimPusan Natl Univ Hosp, Dept Biostat, Busan, South Korea
- Kim, Mi-HyunPusan Natl Univ, Sch Med, Dept Internal Med, Busan, South Korea
- Lee, Min KiPusan Natl Univ, Sch Med, Dept Internal Med, Busan, South Korea
- Insu KimCorresponding authorDong A Univ Hosp, Dept Internal Med, 26 Daesingongwon Ro, Busan 49201, South Korea
- Eom, Jung SeopCorresponding authorPusan Natl Univ, Sch Med, Dept Internal Med, Busan, South Korea
Abstract
Purpose Radial probe endobronchial ultrasound (RP-EBUS) accurately locates peripheral lung lesions (PLLs) during transbronchial biopsy (TBB). We performed an updated meta-analysis of the diagnostic yield of TBB for PLLs using RP-EBUS to generate recommendations for the development of the Korean Association of Lung Cancer guidelines. Materials and Methods We systematically searched MEDLINE and EMBASE (from January 2013 to December 2022), and performed a meta-analysis using R software. The diagnostic yield was evaluated by dividing the number of successful diagnoses by the total lesion number. Subgroup analysis was performed to identify related factors. Results Forty-one studies with a total of 13,133 PLLs were included. The pooled diagnostic yield of RP-EBUS was 0.72 (95% confidence interval [CI], 0.70 to 0.75). Significant heterogeneity was observed among studies (χ2=292.38, p < 0.01, I2=86.4%). In a subgroup analysis, there was a significant difference in diagnostic yield based on RP-EBUS findings (within, adjacent to, invisible), with a risk ratio of 1.45 (95% CI, 1.23 to 1.72) between within and adjacent to, 4.20 (95% CI, 1.89 to 9.32) between within and invisible, and 2.59 (95% CI, 1.32 to 5.01) between adjacent to and invisible. There was a significant difference in diagnostic yield based on lesion size, histologic diagnosis, computed tomography (CT) bronchus sign, lesion character, and location from the hilum. The overall complication rate of TBB with RP-EBUS was 6.8% (bleeding, 4.5%; pneumothorax, 1.4%). Conclusion Our study showed that TBB with RP-EBUS is an accurate diagnostic tool for PLLs with good safety profiles, especially for PLLs with within orientation on RP-EBUS or positive CT bronchus sign.
Keywords
BronchoscopyLung neoplasmsMeta-analysisPulmonary noduleRadial probe endobronchial ultrasoundPERIPHERAL PULMONARY-LESIONSGUIDED TRANSBRONCHIAL BIOPSYULTRATHIN BRONCHOSCOPYSAMPLING TECHNIQUESTHIN BRONCHOSCOPEYIELDULTRASONOGRAPHYEBUSGUIDANCESHEATH
Identifiers
- Scopus EID
- 2-s2.0-85190350367
- WoS UID
- 001208949300001
- KCI
- ART003070426



Login
Back to Publication list