Alix-normalized exosomal programmed death-ligand 1 analysis in urine enables precision monitoring of urothelial cancer
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal Ranking
- JCR Q1Scopus Q1
- Journal
- CANCER SCIENCE115(5) · pp.1602 · 2024
- Citation
- Web of Science 12Scopus 12
- FWCI (Scopus)
- 1.35
- JCR IF
- JCR 2023 4.5
- ISSN
- 1347-9032
Authors
- Woo, Hyun-KyungFirst authorInst Basic Sci IBS, Ctr Soft & Living Matter, Ulsan 44919, South Korea
- Park, JuheeInst Basic Sci IBS, Ctr Soft & Living Matter, Ulsan 44919, South Korea
- Kim, Kyung HwanPusan Natl Univ Hosp, Biomed Res Inst, Busan, South Korea
- Ku, Ja YoonPusan Natl Univ Hosp, Biomed Res Inst, Busan, South Korea
- Ha, Hong-kooCorresponding authorPusan Natl Univ Hosp, Biomed Res Inst, Busan, South Korea
- Cho, Yoon-KyoungCorresponding authorInst Basic Sci IBS, Ctr Soft & Living Matter, Ulsan 44919, South Korea
Abstract
Anti-programmed death-ligand 1 (PD-L1) Ab-based therapies have demonstrated potential for treating metastatic urothelial cancer with high PD-L1 expression. Urinary exosomes are promising biomarkers for liquid biopsy, but urine's high variability requires normalization for accurate analysis. This study proposes using the PD-L1/Alix ratio to normalize exosomal PD-L1 signal intensity with Alix, an internal exosomal protein less susceptible to heterogeneity concerns than surface protein markers. Extracellular vesicles were isolated using ExoDisc and characterized using various methods, including ExoView to analyze tetraspanins, PD-L1, and Alix on individual exosomes. On-disc ELISA was used to evaluate PD-L1 and Alix-normalized PD-L1 in 15 urothelial cancer patients during the initial treatment cycle with Tecentriq. Results showed that Alix signal range was relatively uniform, whereas tetraspanin marker intensity varied for individual exosome particles. On-disc ELISA was more reliable for detecting exosomal PD-L1 expression than standard plate ELISA-based measurement. Using exosomal Alix expression for normalization is a more reliable approach than conventional methods for monitoring patient status. Overall, the study provides a practical and reliable method for detecting exosomal PD-L1 in urine samples from patients with urothelial cancer. This paper suggests using exosomal Alix as a reliable normalization method for detecting programmed death-ligand 1 (PD-L1) in urine. The study shows that on-disc ELISA can accurately detect exosomal PD-L1 without surface immobilization. This innovative approach addresses the limitations of traditional normalization methods and offers practical solutions for identifying urinary biomarkers and improving diagnostic and therapeutic approaches for urothelial cancer patients.image