A High-Performance Liquid Chromatography with Photodiode Array Detection Method for Simultaneous Determination of Three Compounds Isolated from Wikstroemia ganpi: Assessment of the Effects on Cytochrome P450-Mediated Metabolism In Vitro and In Vivo
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal Ranking
- JCR Q1Scopus Q1
- Journal
- NUTRIENTS15(18) · #4061 · 2023
- Citation
- Web of Science 5Scopus 7
- FWCI (Scopus)
- 0.61
- JCR IF
- JCR 2022 5.9
- ISSN
- 2072-6643
Authors
- Min-Ji KeemFirst authorPusan Natl Univ, Res Inst Drug Dev, Busan 46241, South Korea
- Seo Seong WookPusan Natl Univ, Coll Pharm, Dept Mfg Pharm, Busan 46241, South Korea
- Kim, TaeyoungPusan Natl Univ, Coll Pharm, Dept Mfg Pharm, Busan 46241, South Korea
- Beom-Geun JoPusan Natl Univ, Res Inst Drug Dev, Busan 46241, South Korea
- Kim, Su-NamKorea Inst Sci & Technol, Nat Prod Res Ctr, Kangnung 25451, South Korea
- Yoon, InsooCorresponding authorPusan Natl Univ, Coll Pharm, Dept Mfg Pharm, Busan 46241, South Korea
- Yang, Min-hyeCorresponding authorPusan Natl Univ, Res Inst Drug Dev, Busan 46241, South Korea
Abstract
In natural products, the content and quality of the marker components differ depending on the part, production area, collection period, and extraction method; therefore, a standardized analysis method is required to obtain consistent results. This study developed a simultaneous analysis method for three marker components (7-methoxylutolin-5-O-glucoseide, pilloin 5-O-beta-d-glucopyranoside, rutarensin) isolated and purified from Wikstroemia ganpi (W. ganpi). Simultaneous analysis was performed using high-performance liquid chromatography with photodiode array detection (HPLC-PDA) method that was validated according to the International Council for Harmonisation (ICH) guidelines. The developed analytical method exhibited linearity (r(2) > 0.999), detection limits (0.72-3.34 mu g/mL), and quantification limits (2.19-10.22 mu g/mL). The relative standard deviation (RSD) value of intra- and inter-day precisions was less than 1.68%, and analyte recoveries (93.42-117.55%; RSD < 1.86%) were validated according to the analytical procedures, and all parameters were within the allowable range. Quantitative analysis of the three marker components from W. ganpi MeOH extract (WGM) showed 7-methoxylutolin-5-O-glucoseide with the highest content (51.81 mg/g). The inhibitory effects of WGM on cytochrome P450 (CYP) substrate drugs were further investigated. The in vitro study revealed that WGM inhibited the CYP3A-mediated metabolism of buspirone and that 7-methoxylutolin-5-O-glucoseide and pilloin 5-O-beta-d-glucopyranoside inhibited the metabolism of buspirone with IC50 values of 2.73 and 18.7 mu M, respectively. However, a single oral dose of WGM did not have significant effects on the pharmacokinetics of buspirone in rats, suggesting that WGM cannot function as an inhibitor of CYP3A-mediated metabolism in vivo.
Keywords
Wikstroemia ganpi7-methoxylutolin-5-O-glucoseideherb-drug interactionHPLC-PDApharmacokineticspilloin 5-O-beta-d-glucopyranosiderutarensinvalidationAGENTSANTIOXIDANTBIOACTIVITYINHIBITIONANTICANCERROOTSSTEMS
Identifiers
- Scopus EID
- 2-s2.0-85172272004
- WoS UID
- 001079944200001



Login
Back to Publication list