Skip to content

Green-Solvent-Processed High-Performance Broadband Organic Photodetectors

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q1Scopus Q1
Journal
ACS APPLIED MATERIALS & INTERFACES15(31) · pp.37748 · 2023
Citation
Web of Science 25Scopus 28
FWCI (Scopus)
1.52
JCR IF
JCR 2022 9.5
ISSN
1944-8244

Authors

  1. Huang, JianfeiFirst authorUniv Calif Santa Barbara, Ctr Polymers & Organ Solids, Santa Barbara, CA 93106 USA
  2. Luong, Hoang MaiUniv Calif Santa Barbara, Ctr Polymers & Organ Solids, Santa Barbara, CA 93106 USA
  3. Lee, JaewonChungnam Natl Univ, Dept Chem Engn & Appl Chem, Daejeon 34134, South Korea
  4. Chae, SangminUniv Calif Santa Barbara, Ctr Polymers & Organ Solids, Santa Barbara, CA 93106 USA
  5. Yi, AhraUniv Calif Santa Barbara, Ctr Polymers & Organ Solids, Santa Barbara, CA 93106 USA
  6. Qu, Zhong-ZeUniv Calif Santa Barbara, Ctr Polymers & Organ Solids, Santa Barbara, CA 93106 USA
  7. Du, ZhifangUniv Calif Santa Barbara, Ctr Polymers & Organ Solids, Santa Barbara, CA 93106 USA
  8. Choi, Dylan G.Univ Calif Santa Barbara, Ctr Polymers & Organ Solids, Santa Barbara, CA 93106 USA
  9. Kim, Hyo JungPusan Natl Univ, Sch Chem Engn, Dept Organ Mat Sci & Engn, Busan 46241, South Korea
  10. Nguyen, Thuc-QuyenCorresponding authorUniv Calif Santa Barbara, Ctr Polymers & Organ Solids, Santa Barbara, CA 93106 USA

Abstract

Solution-processedorganic photodetectors with broadband activityhave been demonstrated with an environmentally benign solvent, ortho-xylene (o-xylene), as the processingsolvent. The organic photodetectors employ a wide band gap polymerdonor PBDB-T and a narrow band gap small-molecule non-fullerene acceptorCO1-4F, both dissolvable in o-xylene at a controlledtemperature. The o-xylene-processed devices haveshown external quantum efficiency of up to 70%, surpassing the counterpartprocessed with chlorobenzene. With a well-suppressed dark current,the device can also present a high specific detectivity of over 10(12) Jones at -2 V within practical operation frequenciesand is applicable for photoplethysmography with its fast response.These results further highlight the potential of green-solvent-processedorganic photodetectors as a high-performing alternative to their counterpartsprocessed in toxic chlorinated solvents without compromising the excellentphotosensing performance.

Keywords

photodetectororganic photodiodebulk heterojunctiongreen solventphotoplethysmogramDARK CURRENT

Identifiers

Scopus EID
2-s2.0-85167482101
WoS UID
001039577200001