DC-Magnetization-Based Eddy Current Testing for Arbitrary Orientation Defects Detection in Ferromagnetic Steel
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal Ranking
- JCR Q3Scopus Q2
- Journal
- IEEE TRANSACTIONS ON MAGNETICS59(5) · 2023
- Citation
- Web of Science 15Scopus 16
- FWCI (Scopus)
- 0.93
- JCR IF
- JCR 2022 2.1
- ISSN
- 0018-9464
Authors
- Dae Yong UmFirst authorPusan Natl Univ, Dept Elect & Elect Engn, Busan 46241, South Korea
- Park, Gwan SooCorresponding authorPusan Natl Univ, Robot Inst Nondestruct Inspect, Busan 46241, South Korea
Abstract
The DC-magnetization based eddy current testing (ECT) has been developed, and probe signals according to defect orientations are investigated. A focusing field probe was highlighted to improve the sensitivity and compared with that of a circular pancake probe. The limit of the focusing field probe is a reduced sensitivity for parallel oriented defects with lateral misalignment due to its narrow detection area, so this problem hinders the probe detecting arbitrary oriented defects. Therefore, in this paper, we have conducted simulation studies to investigate the effect of DC-magnetization on signals of the probe with the different defect orientations. The results show that superimposing DC-magnetization can widen the detection area of the probe on the application to ferromagnetic steel.
Keywords
CoilsDC-magnetizationdefect obliqueeddy current testinglateral misalignmentMagnetic fieldsMagnetic fluxMagnetic hysteresismagnetic permeabilityPermeabilityProbesSensitivity
Identifiers
- Scopus EID
- 2-s2.0-85148424045
- WoS UID
- 000979615000035