Effect of changes in the internal shape of the evaporator on the performance characteristics of the household refrigerator

Document Type
Publications · Journal Article
Registered DB
KCISCIEScopus
Journal Ranking
JCR Q4Scopus Q2KCI Q4
Journal
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY37(2) · pp.739 · 2023
Citation
Web of Science 2Scopus 2KCI 0
FWCI (Scopus)
0.14
JCR IF
JCR 2022 1.6
ISSN
1738-494X

Authors

  1. Kim, HyunseokFirst authorPusan Natl Univ, Sch Mech Engn, Busan 609735, South Korea
  2. Oh BeenPusan Natl Univ, Sch Mech Engn, Busan 609735, South Korea
  3. NA SANG KYUNGREVO Co Ltd, 6 Changi Daero 113beon Gil, Changwon Si 51388, South Korea
  4. Song, SanghoonLG Elect, Home Appliance & Air Solut Co, 84 Wanam Ro, Changwon Si 51554, Gyeongsangnam D, South Korea
  5. Kim, HyunLG Elect, Home Appliance & Air Solut Co, 84 Wanam Ro, Changwon Si 51554, Gyeongsangnam D, South Korea
  6. Park YeseulCorresponding authorPusan Natl Univ, Sch Mech Engn, Busan 609735, South Korea
  7. Choi, GyungminCorresponding authorPusan Natl Univ, Sch Mech Engn, Busan 609735, South Korea

Abstract

© 2023, The Korean Society of Mechanical Engineers and Springer-Verlag GmbH Germany, part of Springer Nature.The performance of the refrigeration system is largely influenced by the heat exchanger, and there are various methods for increasing heat exchange efficiency. In this paper, the effect of changes in the internal shape of an evaporator with different heat transfer areas on the performance under actual refrigerator operating conditions was analyzed. The type of evaporator includes a grooved evaporator and a composite grooved evaporator with a relatively large heat transfer area. The performance evaluation was evaluated by refrigerant optimization, on-off operational test, and steady state energy test. The optimum refrigerant amount for both systems is 76 g. When a composite grooved evaporator was used, monthly energy consumption was relatively saved by 2.7 kWh/month. In addition, the composite grooved evaporator has consumption and 2.2 % higher cooling capacity than the grooved evaporator. In conclusion, COP improved by 1.33 %.

Keywords

Cooling capacityCOPEnergy consumptionEvaporatorMicrofinned tubeRefrigeratorDOMESTIC REFRIGERATORENERGY-CONSUMPTIONR600A