Skip to content

Effects of Different Centrifugation Protocols on the Detection of EGFR Mutations in Plasma Cell-Free DNA

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q1Scopus Q1
Journal
AMERICAN JOURNAL OF CLINICAL PATHOLOGY158(2) · pp.206 · 2022
Citation
Web of Science 8Scopus 8
FWCI (Scopus)
0.79
JCR IF
JCR 2021 5.4
ISSN
0002-9173

Authors

  1. Shin, Kyung HwaFirst authorPusan Natl Univ Hosp, Dept Lab Med, Busan, South Korea
  2. Lee, Sun MinCorresponding authorPusan Natl Univ, Dept Lab Med, Sch Med, Busan, South Korea
  3. Park, KongkyoungPusan Natl Univ, Dept Lab Med, Yangsan Hosp, Yangsan, South Korea
  4. Choi, HyunjiPusan Natl Univ, Dept Lab Med, Yangsan Hosp, Yangsan, South Korea
  5. Kim, In SukPusan Natl Univ, Dept Lab Med, Sch Med, Busan, South Korea
  6. Yoon, Seong HoonPusan Natl Univ, Pulm Med Ctr, Lung Canc Clin, Yangsan Hosp, Yangsan, South Korea
  7. Oh, Seung HwanPusan Natl Univ, Dept Lab Med, Sch Med, Busan, South Korea

Abstract

Objectives Various preanalytical factors, including the collection tube, storage conditions, and centrifugation, affect the detection results of plasma cell-free DNA (cfDNA). We compared the effect of different centrifugation protocols on the detection of EGFR mutations in cfDNA. Methods We analyzed 117 plasma specimens from 110 patients with non-small cell lung cancer using the cobas EGFR Mutation Test v2 (Roche Diagnostics). We compared the identified EGFR mutations and semiquantitative index values from the 1- and 2-step centrifugation groups and confirmed the clinical impact of differences in the results after further high-speed centrifugation. Results We detected EGFR mutations in 44 (37.6%) and 47 (40.2%) samples that were centrifuged once and twice, respectively; the 2 groups showed an 89.7% (105/117) concordance and a strong correlation in their semiquantitative index values (r = 0.929). Among the 12 inconsistent result pairs, 9 samples of 2-step centrifugation (75%) were consistent with the results of a recent tissue biopsy. Conclusions Additional high-speed centrifugation has been shown to increase the sensitivity of EGFR mutation detection in a commercial in vitro diagnostic real-time polymerase chain reaction device and is an optimal preanalytical factor for detecting low-allele frequency gene mutations using low concentrations of cfDNA.

Keywords

Liquid biopsyEpidermal growth factor receptor mutationsCell-free DNANon-small cell lung cancerPreanalytical factorsCentrifugationLUNG-CANCERACTIVATING MUTATIONSQUANTIFICATIONRESISTANCE

Identifiers

Scopus EID
2-s2.0-85135597455
WoS UID
000768459500001