CFD Evaluation of Heat Transfer and NOx Emissions When Converting a Tangentially Fired Coal Boiler to Use Methane
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal Ranking
- JCR Q3Scopus Q1
- Journal
- ENERGIES15(1) · 2022
- Citation
- Web of Science 12Scopus 14
- FWCI (Scopus)
- 0.77
- JCR IF
- JCR 2021 3.252
- ISSN
- 1996-1073
Authors
- KIM KANG MINFirst authorPusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
- Kim, Gyu-BoPusan Natl Univ, Pusan Clean Energy Res Inst, Busan 46241, South Korea
- Lee, Byoung-HwaPusan Natl Univ, Pusan Clean Energy Res Inst, Busan 46241, South Korea
- BAE YOONHOPusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
- Jeon, ChunghwanCorresponding authorPusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
Abstract
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.The need to reduce global carbon dioxide (CO2 ) emissions is driving the conversion of coal-fired power plants to use methane, which can reduce CO2 emissions by >40%. However, conducting gas firing in coal boilers changes the heat transfer profile; therefore, preliminary evaluations using computational fluid dynamics are required prior to conversion. Here, methane was used as a heat input source in the simulation of an existing coal boiler, and combustion, nitrogen oxides (NOx) emission characteristics, and heat transfer profile changes inside the boiler were analyzed. Furthermore, changes in the burner zone stoichiometric ratio (BZSR) were simulated to restore the decreased heat absorption of the furnace waterwall, revealing that air distribution could change the heat absorption of the waterwall and tube bundles. However, this change was smaller than that caused by conversion from coal to methane. Therefore, to implement gas firing in coal boilers, alternatives such as output derating, using an attemperator, or modifying heat transfer surfaces are necessary. Despite these limitations, a 70% reduction in NOx emissions was achieved at a BZSR of 0.76, compared with coal. As the BZSR contributes significantly to NOx emissions, conducting gas firing in existing coal boilers could significantly reduce NOx and CO2 emissions.
Keywords
Computational fluid dynamicsConversion to methaneFurnace exit gas temperatureHeat transferNitrogen oxidesTangentially fired coal boilerPOWER-PLANTSCOMBUSTIONFLEXIBILITYFUTUREMODELGAS
Identifiers
- Scopus EID
- 2-s2.0-85122035987
- WoS UID
- 000751013500001



Login
Back to Publication list