Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels
- Document Type
- Publications · Journal Article
- Registered DB
- ESCIKCIScopus
- Journal Ranking
- KCI Q4
- Journal
- NEUROINTERVENTION16(3) · pp.240 · 2021
- Citation
- Scopus 22KCI 1
- FWCI (Scopus)
- 0.21
- ISSN
- 2093-9043
Authors
- Ihn, Yon-KwonFirst authorCorresponding authorDepartment of Radiology, St. Vincent’s Hospital, The Catholic University of Korea, Suwon, Korea
- Kim, Bum-sooDepartment of Radiology, Seoul St. Mary’s Hospital, The Catholic University of Korea, Seoul, Korea
- Jeong, Hae WoongDepartment of Radiology, Busan Paik Hospital, Inje University, Busan, Korea
- Suh, Sang HyunDepartment of Radiology, Gangnam Severance Hospital, Yonsei University, Seoul, Korea
- Won, Yoo DongDepartment of Radiology, Uijeongbu St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Korea
- Lee, Young-JunDepartment of Radiology, Hanyang University College of Medicine, Seoul, Korea
- Kim, Dong JoonDepartment of Radiology, Severance Hospital, Yonsei Unviersity College of Medicine, Seoul, Korea
- Jeon, PyongDepartment of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Ryu, Chang-WooDepartment of Radiology, Kyung Hee University Hospital at Gangdong, Seoul, Korea
- Suh, Sang-ilDepartment of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea
- Choi, Dae SeobDepartment of Radiology, Gyeongsang National University Hospital, Gyeongsang National University School of Medicine, Jinju, Korea
- Choi, See SungDepartment of Radiology, Wonkwang University Hospital, Iksan, Korea
- Kim, Sang HeumDepartment of Radiology, CHA Bundang Medical Center, CHA University, Seongnam, Korea
- Byun, Jun SooDepartment of Radiology, Chung-Ang University Hospital, Seoul, Korea
- Jieun RohDepartment of Radiology, Pusan National University Yangsan Hospital, Yangsan, Korea
- Song, YunsunDepartment of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
- Jeong, Woo SangDepartment of Radiology, Ajou University Medical Center, Ajou University School of Medicine, Suwon, Korea
- Hong, NoahDepartment of Neurosurgery, Seoul National University Hospital, Seoul, Korea
- Baik, Sung HyunDepartment of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
- Park, Jeong JinDepartment of Neurology, Konkuk University Medical Center, Seoul, Korea
- Lim, Soo MeeDepartment of Radiology, Ewha Womans University Seoul Hospital, Seoul, Korea
- Kim, Jung-JaeDepartment of Neurosurgery, Ewha Womans University Seoul Hospital, Seoul, Korea
- Yoon, WoongDepartment of Radiology, Chonnam National University Hospital, Gwangju, Korea
Abstract
Purpose: To assess patient radiation doses during diagnostic and therapeutic neurointerventional procedures from multiple centers and propose dose reference level (RL). Materials and Methods: Consecutive neurointerventional procedures, performed in 22 hospitals from December 2020 to June 2021, were retrospectively studied. We collected data from a sample of 429 diagnostic and 731 therapeutic procedures. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time (FT), and total number of image frames (NI) were obtained. RL were calculated as the 3rd quartiles of the distribution. Results: Analysis of 1160 procedures from 22 hospitals confirmed the large variability in patient dose for similar procedures. RLs in terms of DAP, CAK, FT, and NI were 101.6 Gy·cm2, 711.3 mGy, 13.3 minutes, and 637 frames for cerebral angiography, 199.9 Gy·cm2, 3,458.7 mGy, 57.3 minutes, and 1,000 frames for aneurysm coiling, 225.1 Gy·cm2, 1,590 mGy, 44.7 minutes, and 800 frames for stroke thrombolysis, 412.3 Gy·cm2, 4,447.8 mGy, 99.3 minutes, and 1,621.3 frames for arteriovenous malformation (AVM) embolization, respectively. For all procedures, the results were comparable to most of those already published. Statistical analysis showed male and presence of procedural complications were significant factors in aneurysmal coiling. Male, number of passages, and procedural combined technique were significant factors in stroke thrombolysis. In AVM embolization, a significantly higher radiation dose was found in the definitive endovascular cure group. Conclusion: Various RLs introduced in this study promote the optimization of patient doses in diagnostic and therapeutic interventional neuroradiology procedures. Proposed 3rd quartile DAP (Gy·cm2) values were 101.6 for diagnostic cerebral angiography, 199.9 for aneurysm coiling, 225.1 for stroke thrombolysis, and 412.3 for AVM embolization. Continual evolution of practices and technologies requires regular updates of RLs.
Keywords
Cerebral angiographyDiagnostic reference levelsRadiation monitoringIntracranial aneurysmThrombectomyIntracranial arteriovenous malformation
Identifiers
- Scopus EID
- 2-s2.0-85166431834
- KCI
- ART002773596



Login
Back to Publication list