Skip to content

Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels

Document Type
Publications · Journal Article
Registered DB
ESCIKCIScopus
Journal Ranking
KCI Q4
Journal
NEUROINTERVENTION16(3) · pp.240 · 2021
Citation
Scopus 22KCI 1
FWCI (Scopus)
0.21
ISSN
2093-9043

Authors

  1. Ihn, Yon-KwonFirst authorCorresponding authorDepartment of Radiology, St. Vincent’s Hospital, The Catholic University of Korea, Suwon, Korea
  2. Kim, Bum-sooDepartment of Radiology, Seoul St. Mary’s Hospital, The Catholic University of Korea, Seoul, Korea
  3. Jeong, Hae WoongDepartment of Radiology, Busan Paik Hospital, Inje University, Busan, Korea
  4. Suh, Sang HyunDepartment of Radiology, Gangnam Severance Hospital, Yonsei University, Seoul, Korea
  5. Won, Yoo DongDepartment of Radiology, Uijeongbu St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Korea
  6. Lee, Young-JunDepartment of Radiology, Hanyang University College of Medicine, Seoul, Korea
  7. Kim, Dong JoonDepartment of Radiology, Severance Hospital, Yonsei Unviersity College of Medicine, Seoul, Korea
  8. Jeon, PyongDepartment of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
  9. Ryu, Chang-WooDepartment of Radiology, Kyung Hee University Hospital at Gangdong, Seoul, Korea
  10. Suh, Sang-ilDepartment of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea
  11. Choi, Dae SeobDepartment of Radiology, Gyeongsang National University Hospital, Gyeongsang National University School of Medicine, Jinju, Korea
  12. Choi, See SungDepartment of Radiology, Wonkwang University Hospital, Iksan, Korea
  13. Kim, Sang HeumDepartment of Radiology, CHA Bundang Medical Center, CHA University, Seongnam, Korea
  14. Byun, Jun SooDepartment of Radiology, Chung-Ang University Hospital, Seoul, Korea
  15. Jieun RohDepartment of Radiology, Pusan National University Yangsan Hospital, Yangsan, Korea
  16. Song, YunsunDepartment of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
  17. Jeong, Woo SangDepartment of Radiology, Ajou University Medical Center, Ajou University School of Medicine, Suwon, Korea
  18. Hong, NoahDepartment of Neurosurgery, Seoul National University Hospital, Seoul, Korea
  19. Baik, Sung HyunDepartment of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
  20. Park, Jeong JinDepartment of Neurology, Konkuk University Medical Center, Seoul, Korea
  21. Lim, Soo MeeDepartment of Radiology, Ewha Womans University Seoul Hospital, Seoul, Korea
  22. Kim, Jung-JaeDepartment of Neurosurgery, Ewha Womans University Seoul Hospital, Seoul, Korea
  23. Yoon, WoongDepartment of Radiology, Chonnam National University Hospital, Gwangju, Korea

Abstract

Purpose: To assess patient radiation doses during diagnostic and therapeutic neurointerventional procedures from multiple centers and propose dose reference level (RL). Materials and Methods: Consecutive neurointerventional procedures, performed in 22 hospitals from December 2020 to June 2021, were retrospectively studied. We collected data from a sample of 429 diagnostic and 731 therapeutic procedures. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time (FT), and total number of image frames (NI) were obtained. RL were calculated as the 3rd quartiles of the distribution. Results: Analysis of 1160 procedures from 22 hospitals confirmed the large variability in patient dose for similar procedures. RLs in terms of DAP, CAK, FT, and NI were 101.6 Gy·cm2, 711.3 mGy, 13.3 minutes, and 637 frames for cerebral angiography, 199.9 Gy·cm2, 3,458.7 mGy, 57.3 minutes, and 1,000 frames for aneurysm coiling, 225.1 Gy·cm2, 1,590 mGy, 44.7 minutes, and 800 frames for stroke thrombolysis, 412.3 Gy·cm2, 4,447.8 mGy, 99.3 minutes, and 1,621.3 frames for arteriovenous malformation (AVM) embolization, respectively. For all procedures, the results were comparable to most of those already published. Statistical analysis showed male and presence of procedural complications were significant factors in aneurysmal coiling. Male, number of passages, and procedural combined technique were significant factors in stroke thrombolysis. In AVM embolization, a significantly higher radiation dose was found in the definitive endovascular cure group. Conclusion: Various RLs introduced in this study promote the optimization of patient doses in diagnostic and therapeutic interventional neuroradiology procedures. Proposed 3rd quartile DAP (Gy·cm2) values were 101.6 for diagnostic cerebral angiography, 199.9 for aneurysm coiling, 225.1 for stroke thrombolysis, and 412.3 for AVM embolization. Continual evolution of practices and technologies requires regular updates of RLs.

Keywords

Cerebral angiographyDiagnostic reference levelsRadiation monitoringIntracranial aneurysmThrombectomyIntracranial arteriovenous malformation