Skip to content

Methane Gas Cofiring Effects on Combustion and NO xEmission in 550 MW Tangentially Fired Pulverized-Coal Boiler

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q2Scopus Q2
Journal
ACS OMEGA6(46) · pp.31132 · 2021
Citation
Web of Science 17Scopus 20
FWCI (Scopus)
0.69
JCR IF
JCR 2020 3.512
ISSN
2470-1343

Authors

  1. KIM KANG MINFirst authorPusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
  2. Kim, Gyu-BoPusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
  3. Lee, Byoung-HwaPusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
  4. Jeon, ChunghwanCorresponding authorPusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
  5. Keum, Joon-HoKorea Midland Power Co Ltd, Boryeong Power Plant, Boryeong Si 33408, Chungcheongnam, South Korea

Abstract

© 2021 The Authors. Published by American Chemical Society.A shift from coal to liquefied natural gas for electricity generation can mitigate CO2 emissions and respond to the intermittent and variable characteristics of renewable energy. With this objective, numerical simulation was performed in this study to determine the optimal position of the methane injector and evaluate the achievable reduction in NOx emissions before applying methane cofiring to an existing 550 MW tangentially fired pulverized-coal boiler (Boryeong Unit 3). The combustion and NOx reduction in the furnace were intensively analyzed based on the methane cofiring rate (up to 40%). The optimal position of the methane injector was found to be inside the oil port based on the spatial distribution of NOx and the stoichiometric ratio along the furnace height. The NOx reduction rate was logarithmically proportional to the methane cofiring rate, and compared to the base case, a 69.8% reduction was achieved at the 40% cofiring rate. In addition, the fraction of unburned char at the boiler outlet was equivalent to that of the existing boiler as the increase in the flow rates of the close-coupled and separated overfire air improved fuel and air mixing. Simultaneously, methane cofiring led to a reduction in the total fuel loss and CO emissions. Finally, this study showed that the recommended optimum cofiring rate was 20% based on the furnace exit gas temperature. Under the 20% methane cofiring condition, the boiler achieved a 57.3% reduction in NOx emissions and a 7.4% improvement in fuel loss.

Keywords

REDUCTIONMODEL

Identifiers

Scopus EID
2-s2.0-85120181816
WoS UID
000754397700027