Flexible and highly sensitive three-axis pressure sensors based on carbon nanotube/polydimethylsiloxane composite pyramid arrays
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal Ranking
- JCR Q2Scopus Q1
- Journal
- SENSORS AND ACTUATORS A-PHYSICAL331 · #113034 · 2021
- Citation
- Web of Science 44Scopus 52
- FWCI (Scopus)
- 2.72
- JCR IF
- JCR 2020 3.407
- ISSN
- 0924-4247
Authors
- Jung YoungFirst authorPusan Natl Univ, Grad Sch Mech Engn, Busan 46241, South Korea
- Jung, Kyung KukKorea Marine Equipment Res Inst, Qual & Stand Dept, Busan 49111, South Korea
- KIM DONG HWANPusan Natl Univ, Grad Sch Mech Engn, Busan 46241, South Korea
- KWAK DONG HWAPusan Natl Univ, Grad Sch Mech Engn, Busan 46241, South Korea
- Ahn, SeokyoungPusan Natl Univ, Grad Sch Mech Engn, Busan 46241, South Korea
- Han, Jeong SamAndong Natl Univ, Grad Sch Mech Engn, Andong 36729, South Korea
- Ko, Jong SooCorresponding authorPusan Natl Univ, Grad Sch Mech Engn, Busan 46241, South Korea
Abstract
The development of flexible and sensitive three-axis pressure sensors is of great interest for various wearable applications, such as electronic skin, soft robotics, and health monitoring. This study aims to propose a highly sensitive and flexible pressure sensor that can measure three-axis pressure based on conductive microstructured carbon nanotubes (CNTs) and polydimethylsiloxane (PDMS) elastomer with a simple and large-scale fabrication method that uses a polymer wet etching process. The randomly exposed CNTs on the surface using PDMS wet etching improve the sensitivity of the pressure sensors. The fabricated sensors exhibit a high sensitivity of 1.39 kPa(-1) for a pressure range of 250 Pa, excellent limit of detection capability of 1.26 Pa, fast response time of within 52 ms, and high reliability of over 10,000 times of pressure loading/unloading. As an application, the pressure sensors are demonstrated using electronic skin on human fingers for the detection of the pressure levels and pattern recognition of distributed pressure. Moreover, to measure the three-axis pressure, pressurization tests are conducted using artificial fingers, demonstrating that the fabricated sensor can successfully measure the pressures applied along the three axes. (C) 2021 Published by Elsevier B.V.
Keywords
Carbon nanotubePDMSPressure sensorsThree-axisMicrostructureELECTRONIC SKINSTRAIN SENSOR
Identifiers
- Scopus EID
- 2-s2.0-85113620757
- WoS UID
- 000702771400006



Login
Back to Publication list