Full-scale field testing of a precast concrete buried arch bridge with steel outriggers: Field loading test
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal Ranking
- JCR Q1Scopus Q1
- Journal
- ENGINEERING STRUCTURES242 · 2021
- Citation
- Web of Science 11Scopus 10
- FWCI (Scopus)
- 0.44
- JCR IF
- JCR 2020 4.471
- ISSN
- 0141-0296
Authors
- Jeon, Seok HyeonFirst authorDepartment of Civil Engineering, College of Construction & Environmental Engineering, Gyeongsang National University, Jinju 52725, Republic of Korea
- Yim, Hong-jaeDepartment of Civil Engineering, Pusan National University, Busan 46241, Republic of Korea
- Huh, JungwonDepartment of Civil Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
- Cho, Kwang-IlR&D Team, Tekhan Inc., Seongnam 13524, Republic of Korea
- Ahn, Jin-HeeCorresponding authorDepartment of Civil Engineering, College of Construction & Environmental Engineering, Gyeongsang National University, Jinju 52725, Republic of Korea
Abstract
In this study, field loading tests were conducted to examine the structural response and behaviors of a new type of precast concrete buried arch bridge with steel outriggers (PCASO), consisting of multiple straight precast segments (panels), steel outriggers, and V-strips. Static loading was applied on a full-scale field specimen, approximately 18 m length and 3 m height, for three load cases using concrete weight blocks that quantified its weight one by one using a crane. Finite element (FE) analysis was also conducted following the loading tests on the full-scale field specimen. The loading test results revealed that the deformed shape of the buried arch specimen was similar to the conceptual structural responses of the PCASO system affected by load conditions such as backfill and loading position. The deformed shape for each load case obtained from both the field test results and calculations performed by FE analysis was also compared, and its structural behavior and response calculated using the FE analysis can be confirmed to be relatively similar to the results from the field loading test. Therefore, through this loading test on a full-scale field specimen, the new PCASO system was confirmed to have sufficient structural stability and safety and predictable structural behaviors.
Keywords
Loading testPrecast concrete buried arch bridge with steeloutriggers (PCASO)Arching behaviorsStructural responseBuried arch bridgeFinite element analysis
Identifiers
- Scopus EID
- 2-s2.0-85106642677
- WoS UID
- 000663655700001



Login