Skip to content

Control of Femoral Cannulation with a ProGlide Pre-Closure Device during Cardiac Surgery: Is It Reliable?

Document Type
Publications · Journal Article
Registered DB
KCIScopus
Journal
JOURNAL OF CHEST SURGERY54(3) · pp.179 · 2021
Citation
Scopus 0KCI 0
FWCI (Scopus)
0
ISSN
2765-1606

Authors

  1. Kim, Chang-hunFirst authorDepartment of Thoracic and Cardiovascular Surgery, Pusan National University Yangsan Hospital, Medical Research Institute, Pusan National University School of Medicine, Yangsan, Korea
  2. Ju, Min HoCorresponding authorDepartment of Thoracic and Cardiovascular Surgery, Pusan National University Yangsan Hospital, Medical Research Institute, Pusan National University School of Medicine, Yangsan, Korea
  3. Lim, Mi-HeeDepartment of Thoracic and Cardiovascular Surgery, Pusan National University Yangsan Hospital, Medical Research Institute, Pusan National University School of Medicine, Yangsan, Korea
  4. Lee, CheeHoonDepartment of Thoracic and Cardiovascular Surgery, Pusan National University Yangsan Hospital, Medical Research Institute, Pusan National University School of Medicine, Yangsan, Korea
  5. Je, HyounggonDepartment of Thoracic and Cardiovascular Surgery, Pusan National University Yangsan Hospital, Medical Research Institute, Pusan National University School of Medicine, Yangsan, Korea

Abstract

Background: The use of ProGlide as a percutaneous vascular closure device in cardiac surgery remains inconclusive. This study investigated the clinical outcomes of using Pro- Glide in the percutaneous cannulation of femoral vessels in adult cardiac surgery. Methods: From September 2017 to July 2018, 131 consecutive patients underwent femoral vessel cannulation during cardiac surgery. The ProGlide (Abbott Vascular Inc., San- ta Clara, CA, USA) with percutaneous cannulation was used in 118 patients (mean age, 55.7±15.5 years). The accessibility of femoral cannulation was evaluated through preoper- ative computed tomography. For cannulation, sonography was routinely used. The post- operative ankle-brachial index (ABI) was used to evaluate femoral artery stenosis. Results: Of the 118 patients, 112 (94.9%) and 6 (5.1%) underwent minimally invasive car- diac surgery and median sternotomy, respectively. Most femoral cannulations were per- formed on the right side (98.3%) using 15F to 19F arterial cannulas. The technical success rate of cannulation with ProGlide was 99.2%, with no delayed bleeding or cannulation site-related complications during hospitalization. During follow-up, only 1 patient showed femoral artery stenosis with claudication and was treated with interventional balloon an- gioplasty. The postoperative ABI revealed no significant difference in functional stenosis between the cannulation and non-cannulation sides (n=86; cannulation vs. non-cannula- tion, 1.2±0.1 vs. 1.1±0). Conclusion: Percutaneous femoral cannulation with ProGlide was safe and feasible in adult cardiac surgery. This technique may be a good alternative option in patients requir- ing femoral vessel cannulation for cardiac surgery.

Keywords

Femoral cannulationFemoral arteryProGlideCardiac surgery

Identifiers

Scopus EID
2-s2.0-85132347910
KCI
ART002722328