Skip to content

Diagnostic role of PET or PET/CT for prosthetic joint infection: A systematic review and Meta-analysis

Document Type
Publications · Review Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q4Scopus Q3
Journal
HELLENIC JOURNAL OF NUCLEAR MEDICINE24(1) · pp.83 · 2021
Citation
Web of Science 10Scopus 11
FWCI (Scopus)
0.56
JCR IF
JCR 2020 1.102
ISSN
1790-5427

Authors

  1. Kim, KeunyoungFirst authorDepartment of Nuclear Medicine, Pusan National University Hospital, Busan, Korea
  2. Kim, SeongjangCorresponding authorDepartment of Nuclear Medicine, Pusan National University Yangsan Hospital, Yangsan, 50612, Korea

Abstract

Objective: We aimed to explore the role of the diagnostic accuracy of positron emission tomography/computed tomography (PET/CT) or PET for the detection of periprosthetic infection (PPI) of lower limb arthroplasty through a systematic review and meta-analysis. Methods:The MEDLINE and EMBASE from the earliest available date of indexing through October 31, 2020, were searched for studies evaluating the diagnostic performance of PET or PET/CT for the detection of PPI of lower limb arthroplasty. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR+ and LR-), and constructed summary receiver operating characteristic curves. Results: Across 25 results of 19 studies (826 patients), the pooled sensitivity for PET or PET/CT was 0.88 (95% CI; 0.80-0.93) with heterogeneity (chi(2) =119, P=0.00) and a pooled specificity of 0.89 (95% CI; 0.83-0.93) with heterogeneity (chi(2) =170, P=0.00). Like-lihood ratio syntheses gave an overall positive LR+ of 7.9 (95% CI; 5.1-12.2) and negative LR- of 0.14 (95% CI; 0.08-023). The pooled DOR was 57 (95% CI; 31-106). Conclusion: The PET or PET/CT demonstrated good sensitivity and specificity for the detection of PPI of lower limb arthroplasty. At present, the literature regarding the use of PET or PET/CTfor the detection of PPI of lower limb arthroplasty remains still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of PET or PET/CT for the detection of PPI of lower limb arthroplasty.

Keywords

Positron emission tomographyPETPET/CTArthroplastyInfectionPOSITRON-EMISSION-TOMOGRAPHYTOTAL HIP REPLACEMENTSFDG-PETPERIPROSTHETIC INFECTIONKNEE ARTHROPLASTYBONE-SCINTIGRAPHYTEST ACCURACYF-18-FDGPERFORMANCEMANAGEMENT

Identifiers

Scopus EID
2-s2.0-85105766805
WoS UID