Skip to content

Volumetric change of the latissimus dorsi muscle after postoperative radiotherapy in immediate breast reconstruction with an extended latissimus dorsi musculocutaneous flap

Document Type
Publications · Journal Article
Registered DB
KCIScopus
Journal Ranking
Scopus Q2
Journal
Archives of Plastic Surgery47(2) · pp.135 · 2020
Citation
Scopus 6KCI 2
FWCI (Scopus)
0.87
ISSN
2234-6163

Authors

  1. Park, Tae SeoFirst authorDepartment of Plastic and Reconstructive Surgery, Pusan National University School of Medicine, Yangsan, Korea;
  2. Seo, Jung YeolDepartment of Plastic and Reconstructive Surgery, Pusan National University School of Medicine, Yangsan, Korea;
  3. Razzokov, Anvar S.Medion Hospital, Tashkent, Uzbekistan;
  4. June Seok ChoiDepartment of Plastic and Reconstructive Surgery, Pusan National University School of Medicine, Yangsan, Korea;
  5. Min Wook KimDepartment of Plastic and Reconstructive Surgery, Pusan National University School of Medicine, Yangsan, Korea;
  6. Lee, JaeWooDepartment of Plastic and Reconstructive Surgery, Pusan National University School of Medicine, Yangsan, Korea;
  7. Kim, Hyun-yulBreast Surgery Center, Pusan National University Yangsan Hospital, Yangsan, Korea
  8. Jung Youn-JooBreast Surgery Center, Pusan National University Yangsan Hospital, Yangsan, Korea
  9. Choo, Ki SukDepartment of Radiology, Pusan National University School of Medicine, Yangsan, Korea
  10. Song, Kyeong HoCorresponding authorFour Seasons Plastic Surgery Clinic, Busan, Korea
  11. Su Bong NamDepartment of Plastic and Reconstructive Surgery, Pusan National University School of Medicine, Yangsan, Korea;

Abstract

Background This study aimed to determine the magnitude of volume reduction of the latissimusdorsi (LD) muscle after treatment using only postoperative radiotherapy (PORTx) in patientswho underwent immediate breast reconstruction using an extended LD musculocutaneous(eLDMC) flap after partial mastectomy. Methods We retrospectively reviewed 28 patients who underwent partial mastectomy andan eLDMC flap, received only PORTx, and underwent chest computed tomography (CT) 7 to10 days after surgery and 18±4 months after the end of radiotherapy, from March 2011 toJune 2016. The motor nerve to the LD was resected in all patients. One plastic surgeon performedthe procedures, and the follow-up period was at least 36 months (mean, 46.6months). The author obtained LD measurements from axial CT views, and the measurementswere verified by an experienced radiologist. The threshold for statistical significance was setat P<0.05. Results A statistically significant decrease in the LD volume was found after the end ofPORTx (range, 61.19%–80.82%; mean, 69.04%) in comparison to the measurements obtained7 to 10 days postoperatively (P<0.05). All cases were observed clinically for over 3 years. Conclusions The size of an eLDMC flap should be determined considering an average LD reductionof 69% after PORTx. Particular care should be taken in determining the size of an eLDMCflap if the LD is thick or if it occupies a large portion of the flap.

Keywords

MammaplastyMyocutaneous flapSuperficial back muscles

Identifiers

Scopus EID
2-s2.0-85082685353
KCI
ART002567653