Skip to content

Comprehensive multi-criteria evaluation of water source heat pump systems in terms of building type, water source, and water intake distance

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q1Scopus Q1
Journal
ENERGY AND BUILDINGS236 · 2021
Citation
Web of Science 36Scopus 37
FWCI (Scopus)
1.82
JCR IF
JCR 2020 5.879
ISSN
0378-7788

Authors

  1. Jung, YujunFirst authorDepartment of Mechanical Engineering, Korea University, 409 Innovation Hall Bldg., Anam-Dong, Sungbuk-Gu, Seoul, Republic of Korea
  2. Kim, JoonbyumDepartment of Mechanical Engineering, Korea University, 409 Innovation Hall Bldg., Anam-Dong, Sungbuk-Gu, Seoul, Republic of Korea
  3. Kim, HeejoonDepartment of Mechanical Engineering, Korea University, 409 Innovation Hall Bldg., Anam-Dong, Sungbuk-Gu, Seoul, Republic of Korea
  4. Nam, YujinDepartment of Architectural Engineering, Pusan National University, 2 Busandaehak-ro 63, Geomjeong-gu, Busan, Republic of Korea
  5. Cho, HonghyunDepartment of Mechanical Engineering, Chosun University, 309 Pilmundaero, Dong-Gu, Gwangju, Republic of Korea
  6. Lee, HoseongCorresponding authorDepartment of Mechanical Engineering, Korea University, 409 Innovation Hall Bldg., Anam-Dong, Sungbuk-Gu, Seoul, Republic of Korea

Abstract

The performance of water source heat pump (WSHP) systems for heating or cooling buildings depends heavily on conditions such as heating and cooling demands, the water source used, and the distance to the water source. The environmental impact and the economics of using such a system are dominant factors that require consideration. Here, the performance of the WSHP system is comprehensively investigated in terms of energy, the environment, and economic feasibility in terms of three different variables: (1) building type, (2) water source, and (3) water intake distance. The building type is divided according to the ratio of heating to cooling; and river, raw, underground, and deep-sea water sources are considered. The water intake distance is analyzed in terms of horizontal and vertical distances. The results confirm that energy savings and carbon emissions are more dependent on the water source used rather than the type of building. The most influential factor in terms of economic feasibility is considered to be the type of building. The water intake distance, particularly the vertical distance, has a significant impact on all criteria in terms of energy, the environment, and economic feasibility. ? 2021 Elsevier B.V. All rights reserved. The performance of water source heat pump (WSHP) systems for heating or cooling buildings depends heavily on conditions such as heating and cooling demands, the water source used, and the distance to the water source. The environmental impact and the economics of using such a system are dominant factors that require consideration. Here, the performance of the WSHP system is comprehensively investigated in terms of energy, the environment, and economic feasibility in terms of three different variables: (1) building type, (2) water source, and (3) water intake distance. The building type is divided according to the ratio of heating to cooling; and river, raw, underground, and deep-sea water sources are considered. The water intake distance is analyzed in terms of horizontal and vertical distances. The results confirm that energy savings and carbon emissions are more dependent on the water source used rather than the type of building. The most influential factor in terms of economic feasibility is considered to be the type of building. The water intake distance, particularly the vertical distance, has a significant impact on all criteria in terms of energy, the environment, and economic feasibility.

Keywords

Water source heat pumpBuilding typeWater sourceWater intake distanceEnvironmentEconomic feasibility

Identifiers

Scopus EID
2-s2.0-85100407877
WoS UID
000634882800002