Skip to content

Evaporator Optimization of Refrigerator Systems Using Quality Analysis

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q3Scopus Q1
Journal
ENERGIES14(3) · 2021
Citation
Web of Science 7Scopus 8
FWCI (Scopus)
0.28
JCR IF
JCR 2020 3.004
ISSN
1996-1073

Authors

  1. NA SANG KYUNGFirst authorSchool of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
  2. Song, SanghunLG Electronics, 391-2, Changwon, 51533, Korea
  3. lee seunghyukSchool of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
  4. Jehwan LeeSchool of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
  5. Kim, HyunLG Electronics, 391-2, Changwon, 51533, Korea
  6. Lee, SungwooLG Electronics, 391-2, Changwon, 51533, Korea
  7. Choi, GyungminCorresponding authorSchool of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
  8. Ahn Seong YoolCorresponding authorSchool of Mechanical Engineering, Pusan National University, Busan, 46241, Korea

Abstract

In this study, evaporator optimization, via both experimental and simulation methods was conducted. To evaluate the evaporator performance, under the optimal system, the compressor operating time and the effects of oil on the refrigerator system were studied. If the temperature of the refrigerator chamber reaches the setting value, the compressor stops working and it leads to the temperature of the refrigerator chamber slowly increasing, due to the heat transfer to the ambient. When the refrigerator temperature is out of the setting range, the compressor works again, and the refrigerator repeats this process until the end of its life. These on/off period can be controlled through the compressor piston movement. To determine the optimal compressor operating conditions, experiments of monthly power consumption were conducted under various compressor working times and the lowest power consumption conditions was determined when the compressor worked continuously. Lubricating oil, the refrigerator system, using oil, also influenced the system performance. To evaluate the effect of oil, oil eliminated and oil systems were compared based on cooling capacity and power consumption. The cooling capacity of the oil eliminated system was 2.6% higher and the power consumption was 3.6% lower than that of the oil system. After determining the optimal operating conditions of the refrigerator system, visualization experiments and simulations were conducted to decide the optimal evaporator and the conventional evaporator size can be reduced by approximately 2.9%.

Keywords

refrigerator systemflow characteristics of refrigerantlubricating oil eliminationvisualization in evaporatorevaporator quality

Identifiers

Scopus EID
2-s2.0-85106244587
WoS UID
000615068300001