Electrochemical immunoassay based on choline oxidase-peroxidase enzymatic cascade
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal Ranking
- JCR Q1Scopus Q1
- Journal
- BIOSENSORS & BIOELECTRONICS171 · 2021
- Citation
- Web of Science 29Scopus 32
- FWCI (Scopus)
- 1.87
- JCR IF
- JCR 2020 10.618
- ISSN
- 0956-5663
Authors
- Yan, KaiFirst authorDepartment of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Korea
- Nandhakumar, PonnusamyDepartment of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Korea
- Bhatia, AmanDepartment of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Korea
- Lee, Nam-SihkEONE Laboratories, Incheon, 22014, South Korea
- Yoon, Young HoEONE Laboratories, Incheon, 22014, South Korea
- Yang, HaesikCorresponding authorDepartment of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Korea
Abstract
Horseradish peroxidase (HRP)-based electrochemical immunoassays are considered promising techniques for point-of-care clinical diagnostics, but the necessary addition of unstable H2O2 in the enzymatic system may hinder their practical application. Although glucose oxidase (GOx) has been widely explored for in situ generation of H2O2 in HRP-based immunoassay, the GOx-catalyzed reduction of oxidized peroxidase substrate may limit the immunosensing performance. Here, we report a sensitive electrochemical immunosensor based on a choline oxidase (ChOx)-HRP cascade reaction. In this design, ChOx catalyzes the oxidation of choline, during which H2O2 is generated in situ and thus oxidizes acetaminophen (APAP) in the presence of HRP. The electrochemical behavior of APAP in the ChOx-HRP cascade was compared with that of the commonly used GOx-HRP cascade, which confirmed that ChOx could be a superior preceding enzyme for sensitive immunoassay based on the bienzymatic cascade. The developed ChOx-HRP cascade was also further explored for a sandwich-type electrochemical immunoassay of parathyroid hormone in artificial and clinical serum. The calculated detection limit was similar to 3 pg/mL, indicating that the ChOx-HRP cascade is especially promising for highly sensitive electrochemical immunoassays when APAP is used as the peroxidase substrate.
Keywords
Electrochemical immunoassayCholine oxidaseHorseradish peroxidaseEnzymatic cascadeParathyroid hormone detectionDIAPHORASE