Skip to content

Design and Development of a Digital Controlled Dielectric Barrier Discharge (DBD) AC Power Supply for Ozone Generation

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q4Scopus Q2
Journal
JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH79(12) · pp.1057 · 2020
Citation
Web of Science 8Scopus 10
FWCI (Scopus)
0
JCR IF
JCR 2019 0.729
ISSN
0022-4456

Authors

  1. THIRUMALASETTY NAGA VAMSI KRISHNAFirst authorCorresponding authorDept. of Electrical and Electronics Engineering, Pusan National University, Busandaehak-ro 63 beongil 2, Busan 46 241, Korea
  2. Putta Hima SreeSchool of Electrical Engineering, Pusan National University, Busandaehak-ro 63 beongil 2, Busan 46 241, Korea
  3. Rao, S. SrinivasaSchool of Mechanical and Mechatronics Engineering, Kyungsung University, 309 Suyeong-ro Nam-gu Busan, 48 434, Rep. of Korea
  4. YEDLURI ANIL KUMARDept. of Electrical and Electronics Engineering, Pusan National University, Busandaehak-ro 63 beongil 2, Busan 46 241, Korea
  5. Kundakarla, Naga BhushanamDept. of Chemistry, Marquette University, Milwaukee, Wisconsin 53 201, United States of America
  6. Kim, Hee-jeeCorresponding authorDept. of Electrical and Electronics Engineering, Pusan National University, Busandaehak-ro 63 beongil 2, Busan 46 241, Korea

Abstract

A digital controlled dielectric barrier discharge (DBD) AC (Alternative current) power supply is designed and investigated. The power source design with a diode bridge rectifier and PWM (Pulse Width Modulation) inverter along with driver circuits are presented. A step-up transformer is designed to carry 4.6 kW and 10 kVp-p for a dielectric barrier discharge (DBD) AC power supply and ozone generation. An STM (STMicroelectronics) microcontroller is employed to control the phase shift angle of the PWM inverter. The operating frequency of the PWM inverter is 25 kHz. Zero voltage detection can be reached and achieves maximum efficiency. Also, a high voltage transformer is included. The practical results shown that the DBD power supply can be controlled at the chosen value and extreme efficiency can be 87.45 % at 4.6 kW/10 kVp-p.

Keywords

Control circuitDiode bridge rectifierHigh voltage transformerPWM inverterSTMDISINFECTIONWATER

Identifiers

Scopus EID
2-s2.0-85104205141
WoS UID
000595639800003