Skip to content

Operation characteristics of a bubbling fluidized bed heat exchanger with internal solid circulation for a 550-MWe ultra-supercritical CFB boiler

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q1Scopus Q1
Journal
ENERGY192 · 2020
Citation
Web of Science 36Scopus 41
FWCI (Scopus)
0
JCR IF
JCR 2019 6.082
ISSN
0360-5442

Authors

  1. Li, DongfangFirst authorSchool of Mechanical Engineering, Pusan Clean Coal Center, Pusan National University, Republic of Korea
  2. Cai, RunxiaKey Laboratory for Thermal Science and Power Engineering of Ministry Education, Department of Energy and Power Engineering, Tsinghua University, China
  3. Zhang, ManKey Laboratory for Thermal Science and Power Engineering of Ministry Education, Department of Energy and Power Engineering, Tsinghua University, China
  4. Yang, HairuiKey Laboratory for Thermal Science and Power Engineering of Ministry Education, Department of Energy and Power Engineering, Tsinghua University, China
  5. Choi, KyeongSamcheok Thermal Power Plant Division, Korea Southern Power Company (KOSPO), Republic of Korea
  6. Ahn, Seok GiSamcheok Thermal Power Plant Division, Korea Southern Power Company (KOSPO), Republic of Korea
  7. Jeon, ChunghwanCorresponding authorSchool of Mechanical Engineering, Pusan Clean Coal Center, Pusan National University, Republic of Korea

Abstract

The world first 550-MWe ultra-supercritical circulating fluidized bed (CFB) boiler is designed with integrated recycle heat exchangers (INTREX) and internal solid circulation. In this research, in order to investigate the heat transfer behavior and the significance of the internal circulation, the operation characteristics of the four INTREXes as final superheaters including heat transfer coefficients and ash flow rates under different load conditions are experimentally studied. The calculation of ash circulating rate shows that as the boiler load decreases, the furnace bed temperature and the circulating ash temperature in the loop seal decrease, while the flow rate of the internal circulation and its proportion to the total solid flux increase as the boiler load decreases. In particular, under 60% load condition, the internal flow rate is found to be higher than that of external flow rate for the two INTREXes located in front of the middle sections of the furnace. This indicates that the internal circulation is of more significance in the low-load condition than in the high-load condition. The key factor determining the internal-circulation flow rate is found to be the bed pressure drop in the furnace. The phenomenon of non-uniform distribution of solid flux among INTREXes is also discussed. (C) 2019 Published by Elsevier Ltd.

Keywords

Fluidized bedHeat exchangerInternal circulationUltra-supercriticalFLOWBEHAVIOR

Identifiers

Scopus EID
2-s2.0-85076048045
WoS UID
000515212800024