Skip to content

Separation detection of different circulating tumor cells in the blood using an electrochemical microfluidic channel modified with a lipid-bonded conducting polymer

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q1Scopus Q1
Journal
BIOSENSORS & BIOELECTRONICS146 · 2019
Citation
Web of Science 41Scopus 44
FWCI (Scopus)
1.94
JCR IF
JCR 2018 9.518
ISSN
0956-5663

Authors

  1. Gurudatt, Nanjanagudu GaneshFirst authorDepartment of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, Busan, 46241, Republic of Korea
  2. Chung, SaeromiDepartment of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, Busan, 46241, Republic of Korea
  3. Kim, Jeong-MinDepartment of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, Busan, 46241, Republic of Korea
  4. Kim, Moo-HyunDepartment of Cardiology, Dong-A University College of Medicine, Busan, 602-715, Republic of Korea
  5. Jung, Dong-KeunDepartment of Laboratory Medicine, Dong-A University College of Medicine, Busan, 602-715, Republic of Korea
  6. Han, Jin-YoungDepartment of Laboratory Medicine, Dong-A University College of Medicine, Busan, 602-715, Republic of Korea
  7. Shim, YoonboCorresponding authorDepartment of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, Busan, 46241, Republic of Korea

Abstract

Different circulating tumor cells (CTCs) in blood were separated and detected through the decoration of anticancer drug on the target cells, along with chemical modification of the microfluidic channel walls using a lipid attached covalently to the conducting polymer. The working principle of the electrochemical microfluidic device was evaluated with experimental parameters affecting on the separation, in terms of mass and surface charge of target species, fluid flow rate, AC amplitude, and AC frequency. The separated CTCs were selectively detected via the oxidation of daunomycin adsorbed specifically at the cells using an electrochemical sensor installed at the channel end. The fluorescence microscopic examination also confirmed the separation of CTCs in the channel. To evaluate the reliability of the method, blood samples from 37 cancer patients were tested. The device was able to separate the CTCs with 92.0 +/- 0.5 % efficiency and 90.9% detection rate.

Keywords

Circulating tumor cellsCancer detectionConducting polymerAmperometric separation detectionElectrochemical microfluidic deviceCANCER-PATIENTSENUMERATIONENRICHMENT

Identifiers

Scopus EID
2-s2.0-85072780897
WoS UID
000497250600008