Skip to content

Dynamic Modeling and Robust Controllers Design for Doubly Fed Induction Generator-Based Wind Turbines under Unbalanced Grid Fault Conditions

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q3Scopus Q1
Journal
ENERGIES12(3) · 2019
Citation
Web of Science 24Scopus 32
FWCI (Scopus)
1.78
JCR IF
JCR 2018 2.707
ISSN
1996-1073

Authors

  1. Khan, ImranFirst authorSchool of Electrical Engineering, Pusan National University, Busan, South Korea
  2. Zeb, KamranSchool of Electrical Engineering, Pusan National University, Busan, South Korea
  3. Din, Waqar UdSchool of Electrical Engineering, Pusan National University, Busan, South Korea
  4. ul Islam, SaifSchool of Electrical Engineering, Pusan National University, Busan, South Korea
  5. Ishfaq, MuhammadSchool of Electrical Engineering, Pusan National University, Busan, South Korea
  6. Hussain, SadamSchool of Electrical Engineering, Pusan National University, Busan, South Korea
  7. Kim, Hee-jeeCorresponding authorSchool of Electrical Engineering, Pusan National University, Busan, South Korea

Abstract

High penetration of large capacity wind turbines into power grid has led to serious concern about its influence on the dynamic behaviors of the power system. Unbalanced grid voltage causing DC-voltage fluctuations and DC-link capacitor large harmonic current which results in degrading reliability and lifespan of capacitor used in voltage source converter. Furthermore, due to magnetic saturation in the generator and non-linear loads distorted active and reactive power delivered to the grid, violating grid code. This paper provides a detailed investigation of dynamic behavior and transient characteristics of Doubly Fed Induction Generator (DFIG) during grid faults and voltage sags. It also presents novel grid side controllers, Adaptive Proportional Integral Controller (API) and Proportional Resonant with Resonant Harmonic Compensator (PR+RHC) which eliminate the negative impact of unbalanced grid voltage on the DC-capacitor as well as achieving harmonic filtering by compensating harmonics which improve power quality. Proposed algorithm focuses on mitigation of harmonic currents and voltage fluctuation in DC-capacitor making capacitor more reliable under transient grid conditions as well as distorted active and reactive power delivered to the electric grid. MATLAB/Simulink simulation of 2 MW DFIG model with 1150 V DC-linked voltage has been considered for validating the effectiveness of proposed control algorithms. The proposed controllers performance authenticates robust, ripples free, and fault-tolerant capability. In addition, performance indices and Total Harmonic Distortions (THD) are also calculated to verify the robustness of the designed controller.

Keywords

Wind Turbine (WT)Doubly Fed Induction Generator (DFIG)unbalanced grid voltageDC-linked voltage controlProportional Resonant with Resonant Harmonic Compensator (PR plus HC) controllerAdaptive Proportional Integral (API) controlpower controlPWM CONVERTERCONTROL STRATEGIESDFIGSYSTEMS

Identifiers

Scopus EID
2-s2.0-85060950565
WoS UID
000460666200122