Skip to content

Conformal Hermetic Sealing of Wireless Microelectronic Implantable Chiplets by Multilayered Atomic Layer Deposition (ALD)

Document Type
Publications · Journal Article
Registered DB
Nature IndexSCIEScopus
Journal Ranking
JCR Q1Scopus Q1
Journal
ADVANCED FUNCTIONAL MATERIALS29(5) · 2019
Citation
Web of Science 73Scopus 83
FWCI (Scopus)
3.18
JCR IF
JCR 2018 15.621
ISSN
1616-301X

Authors

  1. Jeong, JoonsooFirst authorDepartment of Biomedical Engineering, School of Medicine, Pusan National University, Yangsan, South Korea
  2. Laiwalla, FarahSchool of Engineering, Brown University, Providence, United States
  3. Lee, JihunSchool of Engineering, Brown University, Providence, United States
  4. Ritasalo, RiinaPicosun Oy, Espoo, Finland
  5. Pudas, MarkoPicosun Oy, Espoo, Finland
  6. Larson, LawrenceSchool of Engineering, Brown University, Providence, United States
  7. Leung, VincentDepartment of Electrical Engineering, University of California, San Diego, United States
  8. Nurmikko, ArtoCorresponding authorSchool of Engineering, Brown University, Providence, United States

Abstract

A hermetic sealing method of sub-millimeter-sized microelectronic chiplets for wireless body implants is presented by ultrathin and electromagnetically transparent atomic layer deposition (ALD) coatings. Fully 3D conformal encapsulation of wirelessly powered microdevices is demonstrated both with and without opening windows for electrophysiological measurements. The chiplets embedding custom application-specific integrated circuits (ASICs) with radio frequency (RF) transmitters are encapsulated by a stack of alternating layers of hafnium oxide and silicon dioxide to maximize impermeability of water and ionic penetration while minimizing the volume of the packaging material. The hermeticity of the devices is characterized through accelerated aging tests in saline at T = 87 degrees C, while continued functionality is monitored via evaluation of backscattered RF signals (near 1 GHz) to ascertain possible degradation and electronic failure. Earliest failures of wirelessly functional devices occur after more than 180 d of immersion at 87 degrees C. Wireless devices having opening windows through the ALD envelope show no signs of degradation for >100 d. This implies an equivalent lifetime >10 years at T = 37 degrees C. This approach is readily scalable to high throughput batch processing of hundreds of microchiplets, offering a methodology for hermetic packaging of microscale biomedical chronic implants.

Keywords

atomic layer depositionhafnium oxidehermetic packagingneural implantneurograinHAFNIUM OXIDETHIN-FILMENCAPSULATIONCMOSTEMPERATUREDIELECTRICSRECORDINGSDEVICES

Identifiers

Scopus EID
2-s2.0-85058396147
WoS UID
000457453300008