Ultra-low-dose lung screening CT with model-based iterative reconstruction: an assessment of image quality and lesion conspicuity

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q3Scopus Q2
Journal
ACTA RADIOLOGICA59(5) · pp.553 · 2018
Citation
Web of Science 5Scopus 12
FWCI (Scopus)
0.51
JCR IF
JCR 2017 1.823
ISSN
0284-1851

Authors

  1. Ju, Yun HyeFirst authorBiomedical Engineering, Yonsei University, Wonju, South Korea
  2. Lee, GeewonDepartment of Radiology, Pusan National University Hospital, Busan, South Korea
  3. Lee, Ji WonDepartment of Radiology, Pusan National University Hospital, Busan, South Korea
  4. Hong, Seung BaekDepartment of Radiology, Pusan National University Hospital, Busan, South Korea
  5. Suh, Young JuDepartment of Biomedical Sciences, School of Medicine, Inha University, Incheon, South Korea
  6. Jeong, Yeon-jooCorresponding authorDepartment of Radiology, Pusan National University Hospital, Busan, South Korea

Abstract

Background: Reducing radiation dose inevitably increases image noise, and thus, it is important in low-dose computed tomography (CT) to maintain image quality and lesion detection performance. Purpose: To assess image quality and lesion conspicuity of ultra-low-dose CT with model-based iterative reconstruction (MBIR) and to determine a suitable protocol for lung screening CT. Material and Methods: A total of 120 heavy smokers underwent lung screening CT and were randomly and equally assigned to one of five groups: group 1 = 120 kVp, 25 mAs, with FBP reconstruction; group 2 = 120 kVp, 10 mAs, with MBIR; group 3 = 100 kVp, 15 mAs, with MBIR; group 4 = 100 kVp, 10 mAs, with MBIR; and group 5 = 100 kVp, 5 mAs, with MBIR. Two radiologists evaluated intergroup differences with respect to radiation dose, image noise, image quality, and lesion conspicuity using the Kruskal-Wallis test and the Chi-square test. Results: Effective doses were 61-87% lower in groups 2-5 than in group 1. Image noises in groups 1 and 5 were significantly higher than in the other groups (P < 0.001). Overall image quality was best in group 1, but diagnostic acceptability of overall image qualities in groups 1-3 was not significantly different (all P values > 0.05). Lesion conspicuities were similar in groups 1-4, but were significantly poorer in group 5. Conclusion: Lung screening CT with MBIR obtained at 100 kVp and 15 mAs enables a similar to 60% reduction in radiation dose versus low-dose CT, while maintaining image quality and lesion conspicuity.

Keywords

Computed tomography (CT)ultra-low-dose CTlung screeningiterative reconstructionimage qualityradiation doseRADIATION-EXPOSURECHEST