Skip to content

Image quality and radiation dose of CT venography with double dose reduction using model based iterative reconstruction: comparison with conventional CT venography using filtered back projection

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q3Scopus Q2
Journal
ACTA RADIOLOGICA59(5) · pp.546 · 2018
Citation
Web of Science 4Scopus 4
FWCI (Scopus)
0.2
JCR IF
JCR 2017 1.823
ISSN
0284-1851

Authors

  1. Yeo-jin, JeongFirst authorDepartment of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Hospital, Busan, South Korea
  2. Choo, Ki SukCorresponding authorDepartment of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Hospital, Busan, South Korea
  3. Nam, Kyung JinDepartment of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Hospital, Busan, South Korea
  4. Lee, Ji WonDepartment of Radiology, Pusan National University Hospital, Pusan National University School of Medicine, Busan, South Korea
  5. Kim, Jin YouDepartment of Radiology, Pusan National University Hospital, Pusan National University School of Medicine, Busan, South Korea
  6. Hyuk Jae JungDepartment of Vascular surgery, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Busan, South Korea
  7. Lim, Soo JinDepartment of Cardiology, Kim Hae Gang-il Hospital, KyoungNam, South Korea

Abstract

Background: Computed tomography venography (CTV) at low kVp using model-based iterative reconstruction (MBIR) can enhance vascular enhancement with noise reduction. Purpose: To evaluate image qualities and radiation doses of CTV at 80 kVp using MBIR and a small iodine contrast media (CM) dose and to compare these with those of CTV performed using a conventional protocol. Material and Methods: Sixty-five patients (mean age = 58.1 +/- 7.2 years) that underwent CTV for the evaluation of deep vein thrombosis (DVT) and varicose veins were enrolled in this study. Patients were divided into two groups: Group A (35 patients, 80 kVp, MBIR, automatic tube current modulation, CM = 270 mg/mL, 100 mL) and Group B (30 patients, 100 kVp, filtered back projection [FBP], 120 fixed mA, CM = 370 mg/mL, 120 mL). Objective and subjective image qualities of inferior vena cava (IVC), femoral vein (FV), and popliteal vein (PV) were assessed and radiation doses were recorded. Results: Mean vascular enhancement in group A was significantly lower than in group B (P < 0.01). Noise in group A was significantly lower than in group B except for PV and contrast-to-noise ratio were not significantly different in the two groups (P > 0.05). In addition, radiation dose in group A was significantly lower than in group B (P < 0.001). Subjective image quality comparison revealed group A was statistically inferior to group B except for subjective image noise. Conclusion: CTV at 80 kVp using MBIR with small iodine contrast dose provided acceptable image quality at a lower radiation dose than conventional CTV using FBP.

Keywords

Diagnosisradiographymultidetector computed tomographylower extremityveinsLOW KILOVOLTAGE SETTINGSDEEP VENOUS THROMBOSISCOMPUTED-TOMOGRAPHYPULMONARY ANGIOGRAPHYVASCULAR ENHANCEMENTMULTIDETECTOR CTMODULATIONSONOGRAPHYSTANDARDKVP

Identifiers

Scopus EID
2-s2.0-85044143052
WoS UID
000429744900006