Skip to content

Enhancement in the kV Portal Image Contrast Using Depth Normalization for Accurate Patient Localization

Document Type
Publications · Journal Article
Registered DB
KCISCIEScopus
Journal Ranking
JCR Q4Scopus Q3
Journal
JOURNAL OF THE KOREAN PHYSICAL SOCIETY72(4) · pp.539 · 2018
Citation
Web of Science 3Scopus 6KCI 1
FWCI (Scopus)
0.37
JCR IF
JCR 2017 0.493
ISSN
0374-4884

Authors

  1. Jeon, HosangFirst authorDepartment of Radiation Oncology and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  2. Youn, HanbeanDepartment of Radiation Oncology and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  3. Nam, Ji hoCorresponding authorDepartment of Radiation Oncology and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  4. Lee, JayoungDepartment of Radiation Oncology and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  5. Lee, JuhyeDepartment of Radiation Oncology and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  6. Park, DahlDepartment of Radiation Oncology, Pusan National University Hospital, Busan, South Korea
  7. Kim, WontaekDepartment of Radiation Oncology, Pusan National University Hospital, Busan, South Korea
  8. Ki, Yong GanDepartment of Radiation Oncology, Pusan National University Hospital, Busan, South Korea
  9. Kim, DonghyunDepartment of Radiation Oncology, Pusan National University Hospital, Busan, South Korea
  10. Kim, Ho KyungSchool of Mechanical Engineering and Center for Advanced Medical Engineering Research, Pusan National University, Busan, South Korea

Abstract

The X-ray imaging modality has played an important role in the daily verification of a patient's position for accurate radiation treatment (RT), especially in modern RT techniques that require highly precise patient localization. Although cone-beam computer tomography (CBCT) has already been introduced to the RT field, two-dimensional (2D) X-ray portal imagers have been more widely used than CBCT for the daily check of patient localization owing to the lower patient exposure and time consumption. However, the 2D imager practically provide a lower bone-tissue contrast than CBCT. Thus, we propose a method that enhances the image contrast of daily acquired 2D images by using just one CBCT scan during an entire RT course. This method operates on the basis of the depth normalization (DN) technique and requires no artificial data manipulation such as image post-processing filters. We implemented the algorithm for the portal images of a cylindrical phantom and three patients. From DN results, the image contrast for the phantom and the patients increased by factors of 26.3 and 13.4 on average, and their contrast-to-noise ratios were maintained at differences of 8.6% and 7.7% on average, respectively. Moreover, the DN method provided a stronger contrast enhancement at lower doses that could suppress the imaging exposure and thus improve the patient's safety. Therefore, the verification of RT patient localization is expected to be performed more efficiently and accurately by using the DN method.

Keywords

kV image contrastPatient localizationRadiotherapyDepth normalizationDYNAMIC MULTILEAF COLLIMATIONCOMPUTED-TOMOGRAPHYRADIATION-THERAPY

Identifiers

Scopus EID
2-s2.0-85042660854
WoS UID
000426358300011
KCI
ART002321261