Skip to content

Hybrid ECG-gated versus non-gated 512-slice CT angiography of the aorta and coronary artery: image quality and effect of a motion correction algorithm

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q3Scopus Q2
Journal
ACTA RADIOLOGICA59(2) · pp.170 · 2018
Citation
Web of Science 1Scopus 2
FWCI (Scopus)
0
JCR IF
JCR 2017 1.823
ISSN
0284-1851

Authors

  1. Lee, Ji WonFirst authorDepartment of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
  2. Kim, Chang WonDepartment of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
  3. Lee, GeewonDepartment of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
  4. Lee, Han CheolDepartment of Cardiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
  5. Kim, Sang PhilDepartment of Thoracic and Cardiovascular Surgery, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
  6. Choi, BumSungPusan National University School of Medicine and Medical Research Institute, Pusan National University Yangsan Hospital, Yangsan, South Korea
  7. Jeong, Yeon-jooCorresponding authorDepartment of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea

Abstract

Background: Using the hybrid electrocardiogram (ECG)-gated computed tomography (CT) technique, assessment of entire aorta, coronary arteries, and aortic valve can be possible using single-bolus contrast administration within a single acquisition. Purpose: To compare the image quality of hybrid ECG-gated and non-gated CT angiography of the aorta and evaluate the effect of a motion correction algorithm (MCA) on coronary artery image quality in a hybrid ECG-gated aorta CT group. Material and Methods: In total, 104 patients (76 men; mean age = 65.8 years) prospectively randomized into two groups (Group 1 = hybrid ECG-gated CT; Group 2 = non-gated CT) underwent wide-detector array aorta CT. Image quality, assessed using a four-point scale, was compared between the groups. Coronary artery image quality was compared between the conventional reconstruction and motion correction reconstruction subgroups in Group 1. Results: Group 1 showed significant advantages over Group 2 in aortic wall, cardiac chamber, aortic valve, coronary ostia, and main coronary arteries image quality (all P < 0.001). All Group 1 patients had diagnostic image quality of the aortic wall and left ostium. The MCA significantly improved the image quality of the three main coronary arteries (P < 0.05). Moreover, per-vessel interpretability improved from 92.3% to 97.1% with the MCA (P = 0.013). Conclusion: Hybrid ECG-gated CT significantly improved the heart and aortic wall image quality and the MCA can further improve the image quality and interpretability of coronary arteries.

Keywords

X-ray computed tomographyaortacoronary vesselsradiation dosageECG-triggered imaging techniqueDIAGNOSTIC-ACCURACYDISSECTIONRECONSTRUCTION

Identifiers

Scopus EID
2-s2.0-85040832498
WoS UID
000425981200007