Skip to content

The effect of hydraulic bed movement on the quality of chest compressions

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q2Scopus Q1
Journal
AMERICAN JOURNAL OF EMERGENCY MEDICINE35(8) · pp.1075 · 2017
Citation
Web of Science 4Scopus 4
FWCI (Scopus)
0.57
JCR IF
JCR 2016 1.494
ISSN
0735-6757

Authors

  1. Park, Maeng RealFirst authorDepartment of Emergency Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea
  2. Lee, DaesupDepartment of Emergency Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea
  3. Kim, Yong InDepartment of Emergency Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea
  4. Ryu, Ji HoDepartment of Emergency Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea
  5. Cho, Young MoDepartment of Emergency Medicine, Pusan National University Hospital, Busan, South Korea
  6. Hyung Bin KimDepartment of Emergency Medicine, Pusan National University Hospital, Busan, South Korea
  7. Yeom, Seok-RanDepartment of Emergency Medicine, Pusan National University Hospital, Busan, South Korea
  8. Min, Mun-kiCorresponding authorDepartment of Emergency Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea

Abstract

Objectives: The hydraulic height control systems of hospital beds provide convenience and shock absorption. However, movements in a hydraulic bed may reduce the effectiveness of chest compressions. This study investigated the effects of hydraulic bed movement on chest compressions. Materials and methods: Twenty-eight participants were recruited for this study. All participants performed chest compressions for 2 min on a manikin and three surfaces: the floor (Day 1), a firm plywood bed (Day 2), and a hydraulic bed (Day 3). We considered 28 participants of Day 1 as control and each 28 participants of Day 2 and Day 3 as study subjects. The compression rates, depths, and good compression ratios (> 5-cm compressions/all compressions) were compared between the three surfaces. Results: When we compared the three surfaces, we did not detect a significant difference in the speed of chest compressions (p = 0.582). However, significantly lower values were observed on the hydraulic bed in terms of compression depth (p = 0.001) and the good compression ratio (p = 0.003) compared to floor compressions. When we compared the plywood and hydraulic beds, we did not detect significant differences in compression depth (p = 0.351) and the good compression ratio (p = 0.391). Conclusions: These results indicate that the movements in our hydraulic bed were associated with a non-statistically significant trend towards lower-quality chest compressions. (C) 2017 Elsevier Inc. All rights reserved.

Keywords

CARDIOPULMONARY-RESUSCITATIONSIMULATED RESUSCITATIONSTEP STOOLHEIGHTDEPTHCPRPERFORMANCEMANNEQUINPOSITION

Identifiers

Scopus EID
2-s2.0-85014351728
WoS UID
000407941000007