Functional end-arterial circulation of the choroid assessed by using fat embolism and electric circuit simulation
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal Ranking
- JCR Q1Scopus Q1
- Journal
- SCIENTIFIC REPORTS7 · 2017
- Citation
- Web of Science 15Scopus 17
- FWCI (Scopus)
- 0.18
- JCR IF
- JCR 2016 4.259
- ISSN
- 2045-2322
Authors
- Lee, Ji-EunFirst authorCorresponding authorDepartment of Ophthalmology, College of Medicine, Pusan National University, Yangsan, South Korea
- Ahn, Ki SuDepartment of Ophthalmology, College of Medicine, Pusan National University, Yangsan, South Korea
- Park, KeunheungDepartment of Ophthalmology, College of Medicine, Pusan National University, Yangsan, South Korea
- Pak, Gang YunDepartment of Ophthalmology, College of Medicine, Pusan National University, Yangsan, South Korea
- Kim, Hak-jinDepartment of Radiology, College of Medicine, Pusan National University, Yangsan, South Korea
- Byon, IksooDepartment of Ophthalmology, College of Medicine, Pusan National University, Yangsan, South Korea
- Park, Sung-whoDepartment of Ophthalmology, College of Medicine, Pusan National University, Yangsan, South Korea
Abstract
The discrepancy in the choroidal circulation between anatomy and function has remained unsolved for several decades. Postmortem cast studies revealed extensive anastomotic channels, but angiographic studies indicated end-arterial circulation. We carried out experimental fat embolism in cats and electric circuit simulation. Perfusion defects were observed in two categories. In the scatter perfusion defects suggesting an embolism at the terminal arterioles, fluorescein dye filled the non-perfused lobule slowly from the adjacent perfused lobule. In the segmental perfusion defects suggesting occlusion of the posterior ciliary arteries, the hypofluorescent segment became perfused by spontaneous resolution of the embolism without subsequent smaller infarction. The angiographic findings could be simulated with an electric circuit. Although electric currents flowed to the disconnected lobule, the level was very low compared with that of the connected ones. The choroid appeared to be composed of multiple sectors with no anastomosis to other sectors, but to have its own anastomotic arterioles in each sector. Blood flows through the continuous choriocapillaris bed in an end-arterial nature functionally to follow a pressure gradient due to the drainage through the collector venule.
Keywords
OPTICAL COHERENCE TOMOGRAPHYCHORIOCAPILLARIS BLOOD-FLOWPOSTERIOR CILIARY ARTERYMACULAR DEGENERATIONNEOVASCULARIZATIONVASCULATUREANGIOGRAPHYPATTERNSDISEASE
Identifiers
- Scopus EID
- 2-s2.0-85020026294
- WoS UID
- 000402310900003



Login
Back to Publication list