Prediction of entrained droplet fraction in co-current annular gas-liquid flow in vertical pipes
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal Ranking
- JCR Q1Scopus Q1
- Journal
- EXPERIMENTAL THERMAL AND FLUID SCIENCE85 · pp.287 · 2017
- Citation
- Web of Science 41Scopus 47
- FWCI (Scopus)
- 2.22
- JCR IF
- JCR 2016 2.83
- ISSN
- 0894-1777
Authors
- Aliyu, Aliyu M.First authorSchool of Mechanical Engineering, Pusan National University, Busan, South Korea
- Almabrok, Almabrok A.Department of Petroleum Engineering, Faculty of Engineering, Sirte University, Sirte, Libya
- Baba, Yahaya D.Department of Chemical and Petroleum Engineering, Afe Babalola University, Nigeria
- Archibong, Archibong-EsoOil and Gas Engineering Centre, Cranfield University, United Kingdom
- Lao, LiyunOil and Gas Engineering Centre, Cranfield University, United Kingdom
- Yeung, HoiOil and Gas Engineering Centre, Cranfield University, United Kingdom
- Kim, Kyung ChungCorresponding authorSchool of Mechanical Engineering, Pusan National University, Busan, South Korea
Abstract
The entrained droplet fraction is an important parameter in annular two-phase flow, as its correlations are key inputs in flow simulation codes for the prediction of pressure drop and critical heat flux or dryout. Investigators have stressed the importance of extending the validity range of current correlations so that more conditions are covered. This could be achieved for example by including fluids with higher viscosities, a wider range of operating pressures, and increase in the size of pipes used for experiments (most of the data in the literature are from pipes of 50 mm diameter and below). In attempt to improve the latter, experiments were conducted in a 101.6 mm gas liquid flow loop at Cranfield University's Oil and Gas Engineering Laboratory and data on the fraction of droplets were collected in the annular flow regime by measuring the film velocity, from which the droplet fraction was calculated. Comparison of the film velocity by this method and by a mass balance showed close agreement. A capacitance Wire Mesh Sensor was used for flow visualisation in order to distinguish between annular and churn flow. In order to arrive at an improved correlation, over 1300 data points were gathered from other published works. These include air water studies where large pipes of up to 127 mm in diameter were used. The others were from small-diameter pipes and for refrigerant, steam water, air water, and air glycerine flows. Since in the annular regime, the gas flow entrains liquid droplets into the core, their presence alters the properties of the gas core. Therefore, accurate predictions are pivotal for the energy efficient design and operation of facilities in the petroleum and nuclear power industry. The correlation obtained here showed good agreement with the collected databank. (C) 2017 Elsevier Inc. All rights reserved.
Keywords
Droplet entrainmentLarge diameter pipesTwo-phase flowSauter mean diameterWire Mesh Sensor2-PHASE FLOWFILM FLOWGAS/LIQUID FLOW3-FLUID MODELPHASEDIAMETERDISTRIBUTIONSTRANSITIONSDEPOSITIONSTEADY
Identifiers
- Scopus EID
- 2-s2.0-85015661759
- WoS UID
- 000400533300025



Login
Back to Publication list