Skip to content

Therapeutic efficacy and stent patency of transhepatic portal vein stenting after surgery

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q2Scopus Q2
Journal
WORLD JOURNAL OF GASTROENTEROLOGY22(44) · pp.9822 · 2016
Citation
Web of Science 24
JCR IF
JCR 2015 2.787
ISSN
1007-9327

Authors

  1. Ung Bae JeonFirst author부산대학교, 의과대학, 의학과, KO
  2. Kim, Chang WonCorresponding author부산대학교, 의과대학, 의학과, KO
  3. Kim, Tae Un부산대학교, 부산대학교병원, 대학병원, KO
  4. Choo, Ki Suk부산대학교, 의과대학, 의학과, KO
  5. Jang, Joo Yeon부산대학교, 부산대학교병원, 대학병원, KO
  6. Nam, Kyung Jin부산대학교, 부산대학교병원, 대학병원, KO
  7. Chu, Chong Woo부산대학교, 의과대학, 의학과, 외과학교실, KO
  8. Ryu, Je Ho부산대학교, 부산대학교병원, 대학병원, KO

Abstract

AIM To evaluate portal vein (PV) stenosis and stent patency after hepatobiliary and pancreatic surgery, using abdominal computed tomography (CT). METHODS Percutaneous portal venous stenting was attempted in 22 patients with significant PV stenosis (> 50%) after hepatobiliary or pancreatic surgery - diagnosed by abdominal CT. Stents were placed in various stenotic lesions after percutaneous transhepatic portography. Pressure gradient across the stenotic segment was measured in 14 patients. Stents were placed when the pressure gradient across the stenotic segment was > 5 mmHg or PV stenosis was > 50%, as observed on transhepatic portography. Patients underwent follow-up abdominal CT and technical and clinical success, complications, and stent patency were evaluated. RESULTS Stent placement was successful in 21 patients (technical success rate: 95.5%). Stents were positioned through the main PV and superior mesenteric vein (n = 13), main PV (n = 2), right and main PV (n = 1), left and main PV (n = 4), or main PV and splenic vein (n = 1). Patients showed no complications after stent placement. The time between procedure and final follow-up CT was 41-761 d (mean: 374.5 d). Twenty stents remained patent during the entire follow-up. Stent obstruction caused by invasion of the PV stent by a recurrent tumor -was observed in 1 patient in a follow-up CT performed after 155 d after the procedure. The cumulative stent patency rate was 95.7%. Small in-stent low-density areas were found in 11 (55%) patients; however, during successive follow-up CT, the extent of these areas had decreased. CONCLUSION Percutaneous transhepatic stent placement can be safe and effective in cases of PV stenosis after hepatobiliary and pancreatic surgery. Stents show excellent patency in follow-up abdominal CT, despite development of small in-stent low-density areas.

Keywords

LiverVeinStentComputed tomographySurveillanceEfficaceSEGMENTAL LIVER-TRANSPLANTSVENOUS STENOSISPLACEMENTANGIOPLASTYCHILDRENCOMPLICATIONSMANAGEMENTVENOPLASTY

Identifiers

WoS UID
000389844200016