Skip to content

Computed Tomographic Scoring Systems in Sarcoidosis Comparison With Cardiopulmonary Exercise Testing Parameters

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q3Scopus Q2
Journal
JOURNAL OF THORACIC IMAGING31(2) · pp.104 · 2016
Citation
Web of Science 3
JCR IF
JCR 2015 1.723
ISSN
0883-5993

Authors

  1. Jeong, Yeon-jooFirst authorCorresponding authorDepartment of Radiology, Pusan National University Hospital, Pusan National University, School of Medicine, Medial Research Institute, Pusan, South Korea
  2. Lynch, David A.Department of Radiology, Division of Pulmonary and Critical Care Sciences, National Jewish Health, University of Colorado, Denver School of Medicine, Denver, United States
  3. Rho, Ji YoungDepartment of Radiology, Division of Pulmonary and Critical Care Sciences, National Jewish Health, University of Colorado, Denver School of Medicine, Denver, United States
  4. Hamzeh, Nabeel Y.Department of Medicine, Division of Pulmonary and Critical Care Sciences, National Jewish Health, University of Colorado, Denver School of Medicine, Denver, United States
  5. Suh, Young JuDepartment of Biomedical Sciences, School of Medicine, Inha University, Incheon, South Korea

Abstract

Purpose: The aim of the study was to correlate computed tomographic (CT) scoring systems for pulmonary sarcoidosis with cardiopulmonary exercise testing and evaluate which scoring system provides the most reliable information for assessing disease severity and predicting impairment of gas exchange during exercise. Materials and Methods: The institutional review board approved this retrospective study. All 62 patients underwent thin-section CT, pulmonary function tests, and cardiopulmonary exercise test. Two observers scored CT images according to scoring systems published by Remy-Jardin and colleagues. Spearman rank correlation coefficients were calculated between CT patterns and pulmonary functional impairment parameters, and multiple regression analyses were performed to evaluate which CT abnormalities were significantly associated with pulmonary functional impairment parameters. Results: Regardless of scoring system, PaO2max was significantly associated with the subscores of ground-glass opacity, linear opacity, and total CT scores. Multiple regression analyses showed that subscores of ground-glass and linear opacity in the Leung scoring system appeared to explain a significant amount of variance in functional parameters at rest and at maximal exercise. Conclusions: CT findings, particularly ground-glass opacity and linear abnormalities, can explain a significant amount of variance in cardiopulmonary exercise parameters. This suggests that CT-based scoring systems are valid measures of disease severity in sarcoidosis.

Keywords

lung functionsarcoidosishigh-resolution computed tomographyexerciserespiratory functional impairmentPULMONARY SARCOIDOSISTHORACIC SARCOIDOSISCTHRCT

Identifiers

WoS UID
000372983400006