Diagnostic values of thyroglobulin measurement in fine-needle aspiration of lymph nodes in patients with thyroid cancer
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal Ranking
- JCR Q2Scopus Q2
- Journal
- ENDOCRINE49(1) · pp.70 · 2015
- Citation
- Web of Science 39
- JCR IF
- JCR 2014 3.878
- ISSN
- 1355-008X
Authors
- Pak, KyoungjuneFirst authorDepartment of Nuclear Medicine, Pusan National University Hospital, Busan, South Korea
- Suh, SunghwanDepartment of Internal Medicine, Dong-A University College of Medicine, Busan, South Korea
- Hong, HyunsookMedical Research Collaborating Center, Seoul National University College of Medicine, Seoul, South Korea
- Cheon, Gi JeongCorresponding authorDepartment of Nuclear Medicine, Seoul National University College of Medicine, Seoul, South Korea
- Hahn, Seo KyungMedical Research Collaborating Center, Seoul National University College of Medicine, Seoul, South Korea
- Kang, Keon WookDepartment of Nuclear Medicine, Seoul National University College of Medicine, Seoul, South Korea
- Kim, E. EdmundWCU Graduate School of Concergence Science and Technology, Seoul National University College of Medicine, Seoul, South Korea
- Lee, Dong SooDepartment of Nuclear Medicine, Seoul National University College of Medicine, Seoul, South Korea
- Chung, June-KeyDepartment of Nuclear Medicine, Seoul National University College of Medicine, Seoul, South Korea
Abstract
We aimed to evaluate the diagnostic performance of measuring the concentration of thyroglobulin (Tg) in the washout fluid of the needle aspiration (FNATg). We performed a systematic search of MEDLINE (inception to October 2013) and EMBASE (inception to October 2013) for English publications using keywords "thyroid'', "aspiration'', "washout'', and "thyroglobulin''. All searches were limited to human studies. We included studies of FNA-Tg measurement in the washout fluid rinsed with 1 ml of normal saline. Eight studies including 843 lymph nodes (LNs) were eligible for this study. The pooled sensitivity and specificity of preoperative studies are 0.89 [95 % CI 0.82-0.95], 0.60 [0.49-0.70], and those of postoperative studies are 1.0 [0.83-1.0], 1.0 [0.92-1.0]. To determine best cutoffs from each preoperative and postoperative study, the distance between the point (0, 1) and each observed cutoff values (1-specificity, sensitivity) was calculated, and the distance is minimal when the cutoff value of 32.04 for preoperative studies and of 0.9 for postoperative one are selected. FNA-Tg can be used for both preoperative and postoperative evaluation of LN metastasis. Although the cutoff values for the FNA-Tg has not been standardized, preoperative values of 32.04 ng/ml and postoperative values of 0.9 ng/ml are recommended for identifying neck LN metastasis
Keywords
Thyroid cancerBiopsyFine-needleThyroglobulinWASHOUT FLUIDTG MEASUREMENTBIOPSYCARCINOMAMETASTASESANTIBODIESACCURACYLESIONSMASSESASSAY
Identifiers
- WoS UID
- 000355231900009



Login
Back to Publication list