Skip to content

Diagnostic values of thyroglobulin measurement in fine-needle aspiration of lymph nodes in patients with thyroid cancer

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q2Scopus Q2
Journal
ENDOCRINE49(1) · pp.70 · 2015
Citation
Web of Science 39
JCR IF
JCR 2014 3.878
ISSN
1355-008X

Authors

  1. Pak, KyoungjuneFirst authorDepartment of Nuclear Medicine, Pusan National University Hospital, Busan, South Korea
  2. Suh, SunghwanDepartment of Internal Medicine, Dong-A University College of Medicine, Busan, South Korea
  3. Hong, HyunsookMedical Research Collaborating Center, Seoul National University College of Medicine, Seoul, South Korea
  4. Cheon, Gi JeongCorresponding authorDepartment of Nuclear Medicine, Seoul National University College of Medicine, Seoul, South Korea
  5. Hahn, Seo KyungMedical Research Collaborating Center, Seoul National University College of Medicine, Seoul, South Korea
  6. Kang, Keon WookDepartment of Nuclear Medicine, Seoul National University College of Medicine, Seoul, South Korea
  7. Kim, E. EdmundWCU Graduate School of Concergence Science and Technology, Seoul National University College of Medicine, Seoul, South Korea
  8. Lee, Dong SooDepartment of Nuclear Medicine, Seoul National University College of Medicine, Seoul, South Korea
  9. Chung, June-KeyDepartment of Nuclear Medicine, Seoul National University College of Medicine, Seoul, South Korea

Abstract

We aimed to evaluate the diagnostic performance of measuring the concentration of thyroglobulin (Tg) in the washout fluid of the needle aspiration (FNATg). We performed a systematic search of MEDLINE (inception to October 2013) and EMBASE (inception to October 2013) for English publications using keywords "thyroid'', "aspiration'', "washout'', and "thyroglobulin''. All searches were limited to human studies. We included studies of FNA-Tg measurement in the washout fluid rinsed with 1 ml of normal saline. Eight studies including 843 lymph nodes (LNs) were eligible for this study. The pooled sensitivity and specificity of preoperative studies are 0.89 [95 % CI 0.82-0.95], 0.60 [0.49-0.70], and those of postoperative studies are 1.0 [0.83-1.0], 1.0 [0.92-1.0]. To determine best cutoffs from each preoperative and postoperative study, the distance between the point (0, 1) and each observed cutoff values (1-specificity, sensitivity) was calculated, and the distance is minimal when the cutoff value of 32.04 for preoperative studies and of 0.9 for postoperative one are selected. FNA-Tg can be used for both preoperative and postoperative evaluation of LN metastasis. Although the cutoff values for the FNA-Tg has not been standardized, preoperative values of 32.04 ng/ml and postoperative values of 0.9 ng/ml are recommended for identifying neck LN metastasis

Keywords

Thyroid cancerBiopsyFine-needleThyroglobulinWASHOUT FLUIDTG MEASUREMENTBIOPSYCARCINOMAMETASTASESANTIBODIESACCURACYLESIONSMASSESASSAY

Identifiers

WoS UID
000355231900009