Skip to content

A plasmon-assisted fluoro-immunoassay using gold nanoparticle-decorated carbon nanotubes for monitoring the influenza virus

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q1Scopus Q1
Journal
BIOSENSORS & BIOELECTRONICS64 · pp.311 · 2015
Citation
Web of Science 80
JCR IF
JCR 2014 6.409
ISSN
0956-5663

Authors

  1. Lee, JaewookFirst authorCorresponding authorResearch Institute of Green Science and Technology, Shizuoka University, Shizuoka, Japan
  2. Syed Rahin AhmedDepartment of Nano Fusion and Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  3. Oh, Sang JinDepartment of Nano Fusion and Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  4. Kim, JeonghyoDepartment of Nano Fusion and Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  5. Suzuki, TetsuroDepartment of Infectious Diseases, Hamamatsu University School of Medicine, Handa-yama, Hamamatsu, Japan
  6. Parmar, KaushikDepartment of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Canada
  7. Park, Simon S.Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Canada
  8. Lee, JaebeomCorresponding authorDepartment of Nano Fusion and Cogno-Mechatronics Engineering, Pusan National University, Busan, South Korea
  9. Park, Enoch Y.Research Institute of Green Science and Technology, Shizuoka University, Shizuoka, Japan

Abstract

A plasmon-assisted fluoro-immunoassay (PAFI) was developed for the detection of the influenza virus by using Au nanoparticle (Au NP)-decorated carbon nanotubes (AuCNTs) that were synthesized using phytochemical composites at room temperature in deionized water. Specific antibodies (Abs) against the influenza virus were conjugated onto the surface of AuCNTs and cadmium telluride quantum dots (QDs), which had a photoluminescence intensity that varied as a function of virus concentration and a detection limit of 0.1 pg/mL for all three types of influenza viruses examined. The clinically isolated influenza viruses (A/Yokohama/110/2009 (H3N2)) were detected in the range of 50-10,000 PFU/mL, with a detection limit of 50 PFU/mL. From a series of proof-of-concept and clinical experiments, the developed PAFI biosensing system provided robust signal production and enhancement, as well as an excellent selectivity and sensitivity for influenza viruses. This nanoparticle-based technique could be potentially developed as an efficient detection platform for the influenza virus. (C) 2014 Elsevier B.V. All rights reserved.

Keywords

Plasmon-assisted fluoro-immunoassayGold nanoparticle-decorated carbon nanotubeCdTe quantum dotInfluenza virus detection platformPlasmonic resonance energy transferMETAL-ENHANCED FLUORESCENCEHIGHLY SENSITIVE DETECTIONAU NANOPARTICLESCDTE NANOWIRESHYBRIDSFUNCTIONALIZATIONASSEMBLIESANTIBODIESSENSORSGROWTH

Identifiers

WoS UID
000345059100046