Skip to content

Washing-Free Heterogeneous Immunosensor Using Proximity-Dependent Electron Mediation between an Enzyme Label and an Electrode

Document Type
Publications · Journal Article
Registered DB
Nature IndexSCIEScopus
Journal Ranking
JCR Q1Scopus Q1
Journal
ANALYTICAL CHEMISTRY86(9) · pp.4589 · 2014
Citation
Web of Science 51
JCR IF
JCR 2013 5.825
ISSN
0003-2700

Authors

  1. Dutta, GorachandFirst authorDepartment of Chemistry, Chemistry Institute for Functional Materials, Pusan National University, South Korea
  2. Kim, SinyoungDepartment of Laboratory Medicine, Yonsei University College of Medicine, South Korea
  3. Park, SeonhwaDepartment of Chemistry, Chemistry Institute for Functional Materials, Pusan National University, South Korea
  4. Yang, HaesikCorresponding authorDepartment of Chemistry, Chemistry Institute for Functional Materials, Pusan National University, South Korea

Abstract

Washing processes, essential in most heterogeneous labeled assays, have been a big hurdle in simplifying the detection procedure and reducing assay time. Nevertheless, less attention has been paid to washing-free heterogeneous labeled assays. We report a purely washing-free immunosensor that allows fast, sensitive, and single-step detection of prostate-specific antigen in serum with low interference. Proximity-dependent electron mediation of ferrocenemethanol (Fc) between an indium tin oxide (ITO) electrode and a glucose-oxidase (GOx) label allows us to discriminate between a bound and an unbound label: a bound label offers faster electron mediation than an unbound one. The electrooxidation of Fc at a low applied potential (0.13 V vs Ag/AgCl) and a low electrocatalytic ITO electrode and the oxidation of L-ascorbic acid by L-ascorbate oxidase minimize the effect of the interfering species. With a high concentration of glucose (200 mM), the signal and background levels are hardly dependent on the glucose-concentration variation in the sample. The washing-free immunosensor can detect a concentration of ca. 1 pg/mL for mouse IgG in phosphate-buffered saline and a concentration of ca. 10 pg/mL for prostate-specific antigen spiked in female serum after an incubation period of 10 min. The concentrations measured with actual clinical serum samples are in good agreement with the concentrations measured with a commercial instrument, which renders the washing-free heterogeneous immunosensor appealing for practical use.

Keywords

GLUCOSE-OXIDASEIMMUNOASSAYSERUM

Identifiers

WoS UID
000335719900073