Skip to content

New antireflux self-expandable metal stent for malignant lower biliary obstruction: In vitro and in vivo preliminary study

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q2Scopus Q2
Journal
DIGESTIVE ENDOSCOPY25(1) · pp.60 · 2013
Citation
Web of Science 33
JCR IF
JCR 2012 1.61
ISSN
0915-5635

Authors

  1. Kim, Dong-ukFirst authorDepartment of Internal Medicine, Pusan National University, School of Medicine and Biomedical Research Institute, South Korea
  2. Kwon, Chang-IlCorresponding authorDigestive Disease Center, CHA Bundang Medical Center, CHA University, South Korea
  3. Kang, Dae-hwanDepartment of Internal Medicine, Pusan National University, School of Medicine and Biomedical Research Institute, South Korea
  4. Ko, Kwang HyunDigestive Disease Center, CHA Bundang Medical Center, CHA University, South Korea
  5. Hong, Sung PyoDigestive Disease Center, CHA Bundang Medical Center, CHA University, South Korea

Abstract

Aim Antireflux plastic biliary stents prevent duodenal biliary reflux and improve the stent patency rate. However, the efficacy of the antireflux valve in a self-expandable metal stent (SEMS) for a malignant biliary obstruction has not been well established. We evaluated the efficacy of a SEMS with an antireflux valve using in vitro flow studies and determined the impact of reducing duodenobiliary reflux on the stent patency rate. Methods In vitro testing was conducted using a bile perfusion system to evaluate the antegrade and retrograde flow resistance, and to determine the ideal shape for the valve. Then, a prospective case series in humans was conducted with an adequately designed SEMS with an antireflux valve. Results During the study period, five patients with an unresectable non-hilar malignant biliary obstruction underwent insertion of a SEMS with an antireflux valve. Placement of the SEMS with anantireflux valve was successful on the first attempt in all patients, and no procedure-related complications occurred. Follow up was obtained in all cases. Serum bilirubin level did not decrease to the normal range within 1 month in four patients. Stent occlusions occurred in all four patients as a result of valve malfunctions due to sludge impaction or a clog. Therefore, the study was terminated early due to unexpected results. Conclusion SEMS with an antireflux valve was ineffective in patients with non-hilar malignant biliary obstruction due to limitations on current stent technology.

Keywords

antireflux valve in a self-expandable metal stent (AR-SEMS)bile duct obstructionnon-hilar malignant common bile duct strictureplastic biliary stentself-expandable metal stent (SEMS)COMMON BILE-DUCTRANDOMIZED-TRIALPLASTIC STENTSPALLIATION

Identifiers

WoS UID
000313002700010