Skip to content

Characterization of thermally treated Co2+-exchanged zeolite X

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q1Scopus Q1
Citation
Web of Science 13
JCR IF
JCR 2011 5.625
ISSN
0926-3373

Authors

  1. Jeong, Hoon YoungFirst authorDepartment of Geological Sciences, Pusan National University, South Korea
  2. Koh, Dong-ChanGeologic Environment Division, Korea Institute of Geoscience and Mineral Resources, South Korea
  3. Lee, Kwang-SikCorresponding authorDivision of Earth and Environmental Science, Korea Basic Science Institute, South Korea
  4. Lee, Hyun HwiPohang Accelerator Laboratory, Pohang University of Science and Technology (POSTECH), South Korea

Abstract

This study investigated thermal stabilization of Co2+-exchanged zeolite X (Co-X) using scanning electron microscopy (SEM) coupled with energy dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD), X-ray absorption spectroscopy (XAS), and leaching tests. From SEM-EDX analysis, cobalt was dispersed randomly at <= 600 degrees C, suggesting its presence as an extraframework cation in exchange sites. At >= 800 degrees C, cobalt was locally concentrated with Al on the vitreous surface. Consistent with such observations, XRD data indicated that Co-X maintained the zeolite framework at <= 600 degrees C, and that it became vitrified and transformed to nepheline (NaAlSiO4(s)) and cobalt aluminate (CoAl2O4(s)) at >= 800 degrees C. Cobalt-K edge XAS was subjected to both X-ray absorption near-edge spectroscopy (XANES) and extended X-ray absorption fine structure (EXAFS) analyses. In XANES spectra, the pre-edge peaks and edge-shoulders, characteristic of 4-fold coordinated cobalt (e.g., CoAl2O4(s)), were not evident at <= 600 degrees C, but such features were strong at >= 800 degrees C. The EXAFS spectra of Co-X at <= 600 degrees C lacked in the coordination shells beyond the first Co-O shell. In contrast, Co-X at >= 800 degrees C showed the EXAFS spectra similar to CoAl2O4(s). Taken together, cobalt was likely present as 6-fold coordinated Co2+ in exchange sites at <= 600 degrees C and mainly incorporated into a non-exchangeable CoAl2O4-like phase in both vitreous and crystalline forms at 800 degrees C. In agreement with this proposition, leaching tests with concentrated CaCl2 solutions supported the greater stability of cobalt at >800 degrees C. (C) 2012 Elsevier B.V. All rights reserved.

Keywords

Radioactive isotopeCobaltZeoliteEXAFSSEMFAUJASITE ZEOLITESCRYSTAL-STRUCTUREMOLECULAR-SIEVESION-EXCHANGECOBALTSPECTROSCOPYCO2+

Identifiers

WoS UID
000310864100008