Skip to content

Application of a Cu-Co alloy dendrite on glucose and hydrogen peroxide sensors

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q2Scopus Q1
Journal
ELECTROCHIMICA ACTA61 · pp.36 · 2012
Citation
Web of Science 147
JCR IF
JCR 2011 3.832
ISSN
0013-4686

Authors

  1. Noh, Hui BogFirst authorDepartment of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, South Korea
  2. Lee, Kyung-SunDepartment of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, South Korea
  3. Chandra, PranjalDepartment of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, South Korea
  4. Won, Mi-SookBusan Center, Korea Basic Science Institute, South Korea
  5. Shim, YoonboCorresponding authorDepartment of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, South Korea

Abstract

A Cu-Co alloy dendrite with a hierarchical nanostructure was electrochemically synthesized, and it characterized using scanning electron microscope, energy dispersive X-ray spectroscopy, time-of-flight secondary ion mass spectrometry (TOF-SIMS). X-ray diffractometry, X-ray photoelectron spectroscopy, coulometry, and cyclic voltammetry. The catalytic characteristics of the dendrite were examined for its use with highly sensitive glucose and H2O2 sensors. The TOF-SIMS image shows that the Cu-Co alloy dendrite grew homogeneously in a hierarchical structure. The Co2+ ions that formed on the alloy dendrite mainly contributed to glucose oxidation, and the Cu+ ion cooperated synergically with the Co2+ ion. However. Co3+ was mainly involved in the reduction of H2O2, while the reduction with Cu2+ ion cooperated synergically. The major oxidation products of glucose on the dendrite was confirmed to be formate (12-electron oxidation product) through coulometry and product analysis with a HPLC-MS analyzer. The linear calibration plots for the glucose and H2O2 analyses were obtained between 0.5 mu M to 14.0 mM (detection limit was 0.10 +/- 0.05 mu M) and 1.0 mu M to 11.0 mM (detection limit was 0.75 +/- 0.15 mu M), respectively. The performance of the final sensor was evaluated with a human blood sample. (C) 2011 Elsevier Ltd. All rights reserved.

Keywords

Cu-Co alloy dendriteCatalytic reaction mechanismGlucose sensorH2O2 sensorELECTROCHEMICAL REDUCTIONCARBON NANOTUBESCOPPERNANOSTRUCTURESNANOCRYSTALSELECTRODESOXIDATIONNANODENDRITESOXYGENOXIDE

Identifiers

WoS UID
000301216900006