The Optimal Wavelength of Spectrophotometric Broth Microdilution Antifungal Susceptibility Test for Flucytosine and Three Azoles
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal
- Korean Journal of Laboratory Medicine29(4) · pp.324 · 2009
- Citation
- Web of Science 0
- ISSN
- 1598-6535
Authors
- Lee, Ja YoungFirst authorDepartment of Laboratory Medicine, Inje University College of Medicine, South Korea
- Lee, Eun JungDepartment of Laboratory Medicine, Inje University College of Medicine, South Korea
- Kim, Si HyunDepartment of Laboratory Medicine, Inje University College of Medicine, South Korea
- Jeong, Haeng SoonDepartment of Laboratory Medicine, Inje University College of Medicine, South Korea
- Oh, Seung HwanDepartment of Laboratory Medicine, Inje University College of Medicine, South Korea
- Kim, Hye RanDepartment of Laboratory Medicine, Inje University College of Medicine, South Korea
- Lee, Jeong NyeoDepartment of Laboratory Medicine, Inje University College of Medicine, South Korea
- Chang, Chulhun LudgerusDepartment of Laboratory Medicine, Pusan National University School of Medicine, South Korea
- Kho, Weon-GyuPaik Institute for Clinical Research, Inje University College of Medicine, South Korea
- Shin, Jeong HwanCorresponding authorDepartment of Laboratory Medicine, Inje University College of Medicine, South Korea
Abstract
Background : There is no guideline for the appropriate wavelength at which to measure the optical density (OD) value in broth microdilution antifungal susceptibility testing, although a spectrophotometric reading method is commonly used. The present study aimed to analyze the difference in the OD values over the range of visible light and to ascertain the optimal wavelength for the spectrophotometric method of microdilution testing. Methods: We measured the OD of background blank controls of broth medium, antifungal agents, and inocula of five type strains using a Synergy HT multi-detection microplate reader at 5-nm intervals from 380 nm to 760 rim. We also estimated the OD differences between the 50% of growth control and blank control. Results : The OD of the blank control showed a parabola shape with two peaks and steadily decreased at longer wavelengths. The curves of the antifungal agent were similar to those of blank controls, and the influence of each antifungal agent on the OD was minimal. For the difference in OD between 50% of growth control and the blank control, the curve was the opposite of the blank control, and the OD increased steadily at the wavelengths above 600 nm. Conclusions: The range between 600 nm and 700 nm was the optimal wavelength for broth microdilution antifungal susceptibility testing, although any wavelength within the visible light spectrum can be used, (Korean J Lab Med 2009;29:324-30)