Skip to content

Soft sensor using PNN model and rule base for wastewater treatment plant

Document Type
Publications · Conference Paper
Registered DB
SCIEScopus
Journal
Lecture Notes in Computer Science3973 · pp.1261 · 2006
Citation
Web of Science 3
ISSN
0302-9743

Authors

  1. Kim, Y. J.First author부산대학교, 공과대학, 환경공학과, KO
  2. Bae, Hyeon부산대학교, 공과대학, 전기공학과, 전기공학전공, KO
  3. Poo, Kyungmin부산대학교, 공과대학, 환경공학과, KO
  4. Kim, Jongrack
  5. Moon, T. S.부산대학교, 공과대학, 환경공학과, KO
  6. Kim, Sungshin부산대학교, 공과대학, 전기공학과, 전기공학전공, KO
  7. Kim, Chang-Won부산대학교, 공과대학, 환경공학과, KO

Abstract

The biological wastewater treatment plant, which uses microbial community to remove organic matter and nutrients in wastewater, is known as its nonlinear behavior and uncertainty to operate. In spite of strong needs of automatic monitoring of nutrients, it is thought that tremendous expense may be required to install equipments related with remote control system, especially on-line sensors for monitoring organic and nutrient concentrations in the treatment processes. In this research, as a cost-effective tool for replacing expensive on-line sensor, PNN(Polynomial Neural Network) models were developed to estimate the NOx-N and ammonia concentrations by only using on-line values of ORP, DO and pH at the wastewater treatment plant. Developed PNN model could estimate the NOx-N and ammonia profile well. However, the error was increased at the first anoxic period of the first sub-cycle and NOx-N accumulation was occur-red at the sub-cycle. To deal with those errors, the rule-base-compensator was developed based on operational knowledge.

Identifiers

WoS UID
000239485300184